HP Matrix Operating Environment Software User Manual

Page 15

Advertising
background image

remote_storage_id=<unique identifier of the storage system at the

Remote Site>

NOTE:

Volumes in the Storage Replication Group (identified by srg_name) are replicated

between the local storage system (identified by local_storage_id) and the remote storage
system (identified by remote_storage_id).

•

For failoversrg.cmd:

local_sms_name=<name of the Storage Management Server at the Local

Site>

local_sms_username=<user name for the Storage Management Server at

the Local Site>

local_storage_id=<unique identifier of the storage system at the

Local Site>

remote_sms_name=<name of the Storage Management Server at the Remote

Site>

remote_sms_username=<user name for the Storage Management Server at

the Remote Site>

remote_storage_id=<unique identifier of the storage system at the

Remote Site>

srg_name=<name of the Storage Replication Group to be failed over>

use_non_current_data=<yes or no>

NOTE:

A value of yes requires the Storage Replication Group to be failed over even in

cases where the data at the destination site may not be current. A value of no requires storage
failover to fail if the data at the destination is not current.

Example invocations of Matrix recovery management User Defined adapter implementation

•

During Storage Management Server configuration in Matrix recovery management:

<Matrix recovery management installed directory>/STORAGE/EMC/validatesms.cmd sms_name=EMC_SMS1
sms_username=admin

•

During Storage Replication Group configuration in Matrix recovery management:

<Matrix recovery management installed directory>/STORAGE/EMC/validatesrg.cmd sms_name=EMCSE1
sms_username=admin local_storage_id=emc_id1 remote_storage_id=emc_id2 srg_name=SRG1

•

During an Activate operation in Matrix recovery management:

<Matrix recovery management installed directory>/STORAGE/EMC/failoversrg.cmd local_sms_name=EMC_SMS1
local_sms_username=admin local_storage_id=emc_id1 remote_sms_name=EMC_SMS2 remote_user_name=admin
remote_storage_id=emc_id2 srg_name=SRG1 use_non_current_data=yes

Command return code

Commands must return 0 on successful completion, and a nonzero error code indicates failure.

Multiple User Defined storage adapters

Matrix recovery management supports multiple User Defined storage adapters to co-exist in a
Matrix recovery management configuration. For each User Defined storage adapter type, you can
create a new subdirectory and place your implementation of the three commands for that storage
type. For example, to add a storage adapter named EMC, create an EMC subdirectory under

Setting up Storage

15

Advertising