Battery replacement – HP ProLiant DL145 G3 Server User Manual

Page 58

Advertising
background image

Battery replacement 58

Battery replacement

If the server no longer automatically displays the correct date and time, you may need to replace the

battery that provides power to the real-time clock. Under normal use, battery life is 5 to 10 years.

WARNING:

The computer contains an internal lithium manganese dioxide, a vanadium

pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not

properly handled. To reduce the risk of personal injury:

Do not attempt to recharge the battery.

Do not expose the battery to temperatures higher than 60°C (140°F).

Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.

Replace only with the spare designated for this product.

To remove the component:

1.

Power down the server (on page

5

).

2.

Extend the server from the rack, if applicable.

3.

Remove the access panel (on page

5

).

4.

Remove any hardware that will interfere with accessing the battery.

Advertising