AMX Multimode Dimmer Module RDM-MDM User Manual

Installation sheet, Rdm-mdm multimode dimmer module 2400 w

Advertising
background image

Installation Sheet

RDM-MDM Multimode Dimmer Module

2400 W

The RDM-MDM Multimode Dimmer Module is ideally used in situations
where the load is not specified or the load may change at the last moment.
This unit is a unique combination 2400 W Incandescent dimmer,
2400 W Switch, or 2400 W FDB fluorescent dimmer. It consists of a heavy
duty SSR construction for dimming and a heavy duty positive air gap relay
for switching. The RDM-MDM module's 120 and 240-277 VAC ratings are
CE, UL, and C-UL approved.

RDM-MDM UL and C-UL Ratings:

•

120 VAC, 50/60 Hz, 2400 W per circuit

•

240/277 VAC, 50/60 Hz, 2400 W per circuit

Specifications:

•

Dimensions (HW): 10.00" x 2.75" (25.40 cm x 6.99 cm)

•

Phase dependant dimming

•

Use wires rated at 75°C (167°F)

•

Torque terminals to 7 in-lbs (0.8 N/M)

•

Max. wire size: 10 AWG (4 mm²)

•

Wire stripping length: 0.28" (7 mm)

•

Weight: 4.5 lbs (2.04 kg)

•

BTU/hr: 300

•

Control current: 190 mA @ 12 VDC

Suggested Loads:

Caution Pre-Installation Notes:

•

All Class 1 wiring must be connected to proper terminals.

•

All control wiring must be connected to proper terminals.

•

Disconnect power while installing or connecting the unit.

•

Keep top and bottom air vents clear at all times.

•

Test loads for shorts before connecting.

•

Use low-voltage wires with a 300 volt rating or greater.

•

Use field-installed copper conductors.

•

Run all low-voltage and control wires away from heat producing parts

of the dimmer.

•

Each dimming circuit must have a separate neutral connection.

•

All electrical ratings are for continuous duty.

•

For indoor use only.

•

AC lighting loads only.

•

This module may require extra power from the AXlink connection or an

external power supply connected to the control card.

Connecting RDM Series Modules to the RDM-MDM:

FIG. 1 RDM-MDM

• Incandescent

• Two-wire, phase-controlled ballast

• Low-voltage

• Three-wire, phase-controlled ballast

• Neon, cold-cathode

• Switched fluorescent ballast

Line

Neutral

Dimmed

Switched

350 µS Choke

Mechanical Relay

2400 W power device

Low-voltage control
wiring: four-pin connector
to AMX Lighting master
controller

Mounting points

High-voltage
connections

FIG. 2 Connecting RDM series modules to the RDM-MDM

Pin 4 (GND)
Pin 3 (RLY)
Pin 2 (DIM)
Pin 1 (+12 V)

RDM-MDM four-pin module connector

4-pin plug from a RDM series module

Note: The 4-pin plugs from the module
connector to the 4-pin connector on the
master (black plug cover facing up).

Advertising