Machine Foundation

Thoroughness of detail must be stressed with all
foundation work to ensure a stable unit installation,
eliminating possibilities of excessive vibration during
extract.

The washer-extractor must be placed on a smooth
level surface so that the entire base of the machine is
supported and rests on the mounting surface.

The standard installation does not require anchoring
unless mandated by state or local codes.

Static and dynamic loads on the floor or foundation are
shown in Table 2.

Table 2 can be used as a reference when designing
floors and foundations.

IMPORTANT: Mounting bolts MUST be used for
installation on the 18, 25 and 35 models equipped
with steam heat and models installed on metal base
frames. Refer to Mounting Bolt Installation.

Ensure that the machine is installed on a
level floor of sufficient strength and that
the recommended clearances for
inspection and maintenance are provided.
Never allow the inspection and
maintenance space to be blocked.

W488

CAUTION

Floor Load Data

Model

18

25

33

35

40

55

75

100

135

165

200

Kinetic Energy of the
Cylinder, (N/m)

1386

1730

2736

3240

4105

6640

12404

18361

23257

29581

29581

Dynamic Bottom
Load, (N/Hz)

700/16

750/16 1200/16 1200/16 1200/16 1700/15 2000/15 2960/13 3900/13 4960/13 6100/13

Table 2