Supply programming table, Supply relay configuration (no wiring), Primary 220 volt remote liquid supply connection – Alliance Laundry Systems 18 User Manual

Page 54

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Installation

9001000

52

Supply Programming Table

When programming a supply step on the WE-8,
choose between 9 different supply steps. Refer to
Table 8.

NOTE: The Supply button is button 6.

Supply Relay Configuration (No Wiring)

* L1 (220 VAC) wire or terminal for remote liquid supply

connection.

** L2 common wire (220 VAC) or terminal for remote

liquid supply connection.

Figure 35

The supply relay board is set up to give NO Voltage
AC output to the respective terminals. It is a dry
contact closure of the relay. The voltage applied must
be supplied with the jumper configurations. Refer to
Figure 36.

Primary 220 Volt Remote Liquid Supply
Connection

IMPORTANT: When programming a supply step,
supplies 1, 2 and 3 DO NOT control the relays
shown on Figure 36
. Programming supply 1, 2 or 3
ONLY activates water in compartment A, B or C.
Programming supply 4 activates relay 1.
Programming supply 5 on the WE-8 will activate
supply relay 2, etc. Programming supply 4-9 on the
WE-8 will activate supply relay 1-6 on the board,
respectively. Refer to Table 8
.

* L1 (220 VAC) wire or terminal for remote liquid supply

connection.

** L2 common wire (220 VAC) or terminal for remote

liquid supply connection.

Figure 36

Supply 1

Turns on the water valve in compartment A of
the supply box.

Supply 2

Turns on the water valve in compartment B of
the supply box.

Supply 3

Turns on the water valve in compartment C of
the supply box.

Supply 4

Activates supply relay 1.

Supply 5

Activates supply relay 2.

Supply 6

Activates supply relay 3.

Supply 7

Activates supply relay 4.

Supply 8

Activates supply relay 5.

Supply 9

Activates supply relay 6.

Table 8

CFS7N

CFS7N

Supply

Relay

1

1

2

Supply

Relay

2

3

4

Supply

Relay

3

5

6

Supply

Relay

4

7

8

9

10

Supply

Relay

5

Supply

Relay

6

11 12

13* 14**

TYPICAL SUPPLY RELAY BOARD CONFIGURATION

CFS8N

CFS8N

Pump

1

Pump

2

Pump

3

Pump

4

Pump

5

Pump

6

Supply

Relay

1

1

2

Supply

Relay

2

3

4

Supply

Relay

3

5

6

Supply

Relay

4

7

8

9

10

Supply

Relay

5

Supply

Relay

6

11 12

13* 14**

ELECTRICAL CONNECTION OF THE

LIQUID SUPPLY PUMPS

Advertising
This manual is related to the following products:

55, 35, 75, 33, 135, 200, 165, 40, 100