Installation

53

9001000

Supply relay 1 controls terminals 1 and 2. Figure 36
shows the jumper wire from terminal 13 (L1

220

VAC)

to all other even pins (i.e., 2, 4, 6…). This applies L1
(

220

VAC) to terminal 2. When supply 4 on the WE-8

is programmed, this will close supply relay 1 and
apply L1 (

220

VAC) through pin 2 to pin 1. This signal

is used from the terminal to the chemical supply
vendors first pump.

IMPORTANT: Supply 4 must be programmed on
the WE-8 to create the signal on terminal 1. The
chemical vendor will always use terminal 14 as the
common terminal for all pumps. This will apply for
the remainder of the 220 VAC circuit for each of
the pump signals. For the remainder of the relays,
supply relay 2 will control terminals 3 and 4;
supply relay 3 will control terminals 5 and 6; etc.

IMPORTANT: The WE-8 must be programmed
for supply 4-9 to energize the supply relays 1-6
respectively.

Primary 220 Volt Remote Liquid Supply
Connection (Continued)

Figure 37

The 220V can be transformed to other values to drive
other type supply pumps.

Figure 38

Also, pumps with different operating voltage
requirements can be combined.

Figure 39

CFD518N

CFS495N

CFS496N

CFSD518N

EXAMPLE: PUMPS 24V ~

CFS495N

EXAMPLE: 5 PUMPS 220V ~ AND 1 PUMP 24V ~

CFS496N

WITH AN EXTERNAL 24V DC