Table 4-9 addhoststoragedomain command parameters – HP StorageWorks XP10000 Disk Array User Manual
Page 26

Command Line Interface Commands 26
NOTE:
For the StorageWorks XP12000/XP10000 and XP1024/XP128, when AddHostStorageDomain
adds a host storage domain, the LUN security of the target port is automatically enabled.
Table 4-9
AddHostStorageDomain Command Parameters
Parameter Name
Status
Description
domain
Required
DomainID of the host storage domain.
NOTE:
The specifiable values vary, depending on the storage subsystem.
For StorageWorks XP12000/XP10000: 1 to 254
For StorageWorks XP1024/XP128: 1 to 127
All Others: 1 to 511
hostmode
Optional
(StorageWorks
XP12000/XP10000
and XP1024/XP128)
New host connect mode of the Host Storage Domain (normally, Standard).
For the StorageWorks XP12000/XP10000, you can specify the following
values:
Standard
Sequent
HP
Solaris
Netware
Windows
Windows Extension
Tru64
HI-UX
AIX
OPEN-VMS
The following value relies on the DKC microcode version.
For 50-03-0X-XX/XX or later:
UVM
For the StorageWorks XP1024/XP128, you can specify the following values:
Standard
Sequent
HP
Solaris
Netware
Windows
Windows Extension
Tru64
HI-UX
AIX
OPEN-VMS
The following value relies on the DKC microcode version.
For 21-05-00-XX/XX or later:
Windows Extension
Solaris Extension
For 21-14-02-XX/XXor later:
Standard Extension2
HP Extension2
Solaris Extension2
Windows Extension2
hostModeOption
Optional
(StorageWorks
XP12000/XP10000
only)
An option of the host connection mode. To specify two or more options,
separate them with semicolons (;).
For details about the values that you can specify, see
Table 4-36
.
model
Required
Model of the storage array for the Host Storage Domain.
port
Required
Port ID of the Host Storage Domain (a specific array must be specified by
serial number and model).
name