HP StorageWorks XP10000 Disk Array User Manual

Page 61

Advertising
background image

Command Line Interface Commands 61


Table 4-36

hostModeOption Parameter Values and Description

hostModeOption Values Description

2

Specify this value when using VERITAS™ Database Edition/Advanced Cluster for Real
Application Clusters or VERITAS™ Cluster Server 4.0 (I/O fencing feature).

6

Specify this value when all of the following conditions are satisfied:

•

The host connection mode is set to Windows (mode 0C) or Windows Extension (mode 2C).

•

An Emulex

®

host bus adapter is in use.

•

A mini-port driver is in use.

•

The TPRLO parameter for the mini-port driver of the host bus adapter is set to 2.

7

Specify this value when all of the following conditions are satisfied:

•

The host connection mode is set to Standard (mode 00) or Solaris (mode 09).

•

You want to let the system automatically recognize the reduction and increase in the number
of devices while a SUN™ host bus adapter is in use.

12

Specify this value when all of the following conditions are satisfied:

•

The host connection mode is set to HP-UX (mode 03).

•

You want to prevent devices to which no paths have been defined from creating a device file
when the HP-UX host is connected.

13

Specify this value when you want to get a SIM notification when the number of unsuccessful
connections between ports exceeds a threshold.

14

Specify this value when all of the following conditions are satisfied:

•

The host connection mode is set to Tru64 (mode 07).

•

You want to use TruCluster to set up a cluster on both a Continuous Access XP primary and
a secondary volume.

Command execution example: In this example, the CLI command modifies the settings for a port (port number:
16

) of a storage subsystem (serial number: 10001, model: XP1024) as follows. The command:

•

changes the value for the hostmode parameter to Standard, for the port's host storage domain (domain
ID: 0)

•

changes the topology to Fabric(off), FC-AL

•

sets the Fibre Channel address to 73

•

disables LUN security by specifying false

•

sets the transmission speed of the Fibre Channel to 1

hdvmcli ModifyPort -o "D:\logs\XP1024 ModifyPort.log" serialnum=10001 model=XP1024

port=16 domain=0 hostmode=Standard "topology=Fabric(off), FC-AL" fibreaddr=73

lunsec=false channelspeed=1

Command execution result:

RESPONSE:

An instance of StorageArray

.

. (Attributes of StorageArray are omitted here)

.

List of 1 Port elements:

An instance of Port

objectID=PORT.HDS9980V.10001.16

portID=16

portType=Fibre

fibreAddress=73

topology=Fabric(off), FC-AL

displayName=CL2-A

lunSecurityEnabled=false

controllerID=5

worldWidePortName=50.06.0E.80.03.3A.99.10

channelSpeed=1

slprNumber=-1

portRole=Target

List of 1 HostStorageDomain elements:

An instance of HostStorageDomain

Advertising