4-1 Extracting Parameter Values

Some of the parameter values for CLI commands can be found by executing other CLI commands and
extracting the parameter values from the resulting output. For example, in some CLI commands the devnum is
a required parameter. To find a particular devnum parameter you can execute the GetStorageArray
(subtarget=LDEV)

command, specifying only the model and serialnum parameters, and specifying LDEV

for the subtarget parameter. In the resulting output, the devnum value appears under An instance of
LogicalUnit

.

Table 4-1

describes which CLI commands can be used to find which parameter values.

Table 4-1

Extracting Parameter Values

To Find This Parameter Value: Do This:

alertnum

Execute the GetAlerts command. Use the value displayed as alert number under An
instance of Alerts

.

arraygroupobjid

Execute the GetStorageArray (subtarget=ArrayGroup) command, specifying
only the model and serialnum parameters, and ArrayGroup for the subtarget
parameter. Use the array group displayed as objectID.

chassis

Execute the GetStorageArray (subtarget=ArrayGroup) command, specifying
only the model and serialnum parameters, and ArrayGroup for the subtarget
parameter. The chassis value appears in a StorageArray.

ctrlid

Execute the GetStorageArray (subtarget=PortController) command,
specifying only the model and serialnum parameters, and PortController for the
subtarget

parameter. Use the value displayed as controllerID.

configfileid

Execute the GetHost command without specifying any parameters. Use the value
displayed as ConfigFile.

controllernum

Execute the GetStorageArray (subtarget=PortController) command,
specifying only the model and serialnum parameters, and the value for
subtarget=PortController

. Use the value specified as controllerID.

devnum

Execute the GetStorageArray (subtarget=LDEV) command, specifying only the
model

and serialnum parameters, and LDEV for the subtarget parameter, and then

obtain the value from the execution result. In the execution result of this command, the
devNum

value appears in An instance of LogicalUnit.

domain

Execute the GetStorageArray (subtarget=HostStorageDomain) command,
specifying only the model and serialnum parameters, and HostStorageDomain for
the subtarget parameter. Use the domainID value.

groupelements

Execute the GetStorageArray (subtarget=Port, portsubinfo=Path)
command, specifying only the model and serialnum parameters, Port for the
subtarget

parameter, and Path for the portsubinfo parameter. Use the objectID

value.

groupnum

Execute the GetStorageArray (subtarget=ArrayGroup) command, specifying
only the model and serialnum parameters, and ArrayGroup for the subtarget
parameter. Use the number value.

Advertising