3-12-1 getstoragearray (subtarget=arraygroup) – HP StorageWorks XP10000 Disk Array User Manual

Page 36

Advertising
background image

Command Line Interface Commands 36


Command execution example: In this example, the CLI command obtains information about the configuration
of all the storage subsystems managed by the Device Manager server:

hdvmcli GetStorageArray

Command execution result:

RESPONSE:

An instance of StorageArray

objectID=ARRAY.HDS9960.10011

name= [email protected]

description= XP512 (10011) at 10.208.114.140

serialNumber=10011

arrayFamily=HDS9900

arrayType=HDS9960

microcodeVersion=01-13-56/00

agentVersion=02-01-06/00

productName=XP512

controllerVersion=01-18-01-00/00

numberOfControllers=1

capacityInGB=1,326

cacheInMB=7,168

sharedMemoryInMB=-1

numberOfSpareDrives=-1

freeCapacityInGB=701

allocatedCapacityInGB=624

autoLunCapacityInGB=0

onDemandCapacityInGB=0

totalFreeSpaceInGB=124

largestFreeSpaceInGB=63

capacityInKB=1,390,713,840

freeCapacityInKB=735,710,400

allocatedCapacityInKB=655,003,440

autoLunCapacityInKB=0

onDemandCapacityInKB=0

totalFreeSpaceInKB=130,084,560

largestFreeSpaceInKB=67,096,800

multipathSupport=1

securityStatus=1

sequenceNumber=10011

displayArrayFamily=XP512/48

displayArrayType=XP512

numberOfLUs=626

numberOfAllocatedLUs=210

numberOfUnallocatedLUs=416

slprStatus=-1

4-3-12-1 GetStorageArray (subtarget=ArrayGroup)

GetStorageArray (subtarget=ArrayGroup)

obtains information about one or all array groups in one or

all storage subsystems.

Users with access to this command:

Yes: System Administrator, Storage Administrator

No: None

Restricted to permitted resources: Guest, Local System Administrator, Local Storage Administrator, Local
Guest

Table 4-19

GetStorageArray (subtarget=ArrayGroup) Command Parameters

Parameter Name

Status

Description

model

Optional

Model of the storage subsystem. When you omit this parameter, you will
obtain information about the models of all storage subsystems.

Advertising