3-15 modifyport, Modifyport, Table 4-34 modifyport command parameters – HP StorageWorks XP10000 Disk Array User Manual

Page 59

Advertising
background image

Command Line Interface Commands 59


4-3-15 ModifyPort

ModifyPort

will change port and host storage domain attributes.

Users with access to this command:

Yes: System Administrator, Storage Administrator

No: Guest, Local System Administrator, Local Storage Administrator, Local Guest

Format for the StorageWorks XP12000/XP10000:

hdvmcli [URL] ModifyPort [option] serialnum=serial-number model=model port=port-number

[topology=new-port-topology] [fibreaddr=new-fibre-channel-address-for-the-port]

[channelspeed={0|1|2}] [lunsec={true|false}] [domain=domain-ID] [nickname=new-host-

storage-domain-name] [hostmode=new-host-mode-for-the-port] [hostModeOption=new-host-mode-

option-list]

Format for the StorageWorks XP1024/XP128:

hdvmcli [URL] ModifyPort [option] serialnum=serial-number model=model port=port-number

[topology=new-port-topology] [fibreaddr=new-fibre-channel-address-for-the-port]

[channelspeed={0|1|2}] [lunsec={true|false}] [domain=domain-ID] [nickname=new-host-

storage-domain-name] [hostmode=new-host-mode-for-the-port]

Format for the StorageWorks XP512/XP48:

hdvmcli [URL] ModifyPort [option] serialnum=serial-number model=model port=port-number

[topology=new-port-topology] [fibreaddr=new-fibre-channel-address-for-the-port]

[lunsec={true|false}] [domain=domain-ID] [hostmode=new-host-mode-for-the-port]

Table 4-34

ModifyPort Command Parameters

Parameter Name

Status

Description

serialnum

Required

Serial number of the port’s storage array.

model

Required

Model of the port’s storage array.

port

Required

Number of the port.

topology

Optional

New topology value for the port.
Possible values are as follows.

Fabric(on), FC-AL

Fabric(off), FC-AL

Fabric(on), Point-to-Point

Fabric(off), Point-to-Point

fibreaddr

Optional

New fibre channel address for the port (the hex string representation).

channelspeed

Optional
(XP12000/XP10000 and
XP1024/XP128 only)

New transmission speed of a fiber channel for the port.
For StorageWorks XP12000/XP10000 and XP1024/XP128, you can
specify the following values:
0

: automatic

1

: 1 Gb/s

2

: 2 Gb/s

lunsec

Optional

New setting for LUN security enabled (either “true” or “false”).

domain

Optional

DomainID of the Host Storage Domain (please refer to the notes).

nickname

Optional
(XP12000/XP10000 and
XP1024/XP128)

Specify the nickname of the host storage domain. When you specify
this parameter, you must also specify the domain parameter.

The maximum number of characters that can be used for a nickname is
as follows:
StorageWorks XP12000/XP10000: 16 bytes
DKC microcode version 50-04-01 or later: 32 bytes

StorageWorks XP1024/128: 8 bytes

Advertising