8 replication commands, 8-1 addconfigfileforreplication, Replication commands – HP StorageWorks XP10000 Disk Array User Manual

Page 98: Addconfigfileforreplication

Advertising
background image

Command Line Interface Commands 98


An instance of DebugLevel

value=0 [Full Debugging trace]

description=Debugging Trace

4-8 Replication Commands

Replication commands provide management support for the Device Manager server.

4-8-1 AddConfigFileForReplication

AddConfigFileForReplication

creates the Continuous Access XP configuration definition file for RAID

Manager that is required to create copy pairs for Business Copy XP, Continuous Access XP, Continuous
Access XP Extension, and Snapshot XP.

Users with access to this command:

Yes: System Administrator, Storage Administrator

No: Guest, Local Guest

Restricted to permitted resources: Local System Administrator and Local Storage Administrator do not
have access range limitations.

NOTE:

Continuous Access XP Extension can be used for StorageWorks XP Disk Array. Snapshot XP can

be used for StorageWorks XP12000/XP10000.

Table 4-77

AddConfigFileForReplication Command Parameters

Parameter Name

Status

Description

groupname

Required (Method 1)

Group name used in the RAID Manager. You cannot specify a
name that begins with a hash mark (#) or hyphen (-). You can
use 31 or fewer characters.
When using Method 1, specify a group name that is specified in
the definition file.

pvolhostid

Required

Host ID for identifying the P-VOL.
When using Method 1, specify the host ID of the P-VOL in a
group specified in the definition file.

pvolinstancenum

Required (Method 1 or 2)

Instance number of the Continuous Access XP instance for
managing the P-VOL.
When using Method 1, specify the instance number of the P-
VOL of a group specified in the definition file.

pvolportnum

Required (Method 3)

Port number of the Continuous Access XP instance for
managing the P-VOL.

In Solaris™, specify an integer from 0 to 65535.
In AIX

®

, Windows

®

, HP-UX, and Linux

®

, specify an integer

from 1 to 65535.

This parameter is invalid when the pvolinstancenum is
specified.

svolhostid

Required

Host ID for identifying the S-VOL.
When using Method 1, specify the host ID of the S-VOL of a
group specified in the definition file.

svolinstancenum

Required (Method 1 or 2)

Instance number of the Continuous Access XP instance for
managing the S-VOL.
When using Method 1, specify the instance number of the S-
VOL of a group specified in the definition file.

svolportnum

Required (Method 3)

Port number of the Continuous Access XP instance for
managing the S-VOL.

In Solaris™, specify an integer from 0 to 65535.
In AIX

®

, Windows

®

, HP-UX, and Linux

®

, specify an integer

from 1 to 65535.

This parameter is invalid when the svolinstancenum is
specified.

pvolarraytype

Required

Model of the storage subsystem that includes the P-VOL.

Advertising