4-8-1 AddConfigFileForReplication
AddConfigFileForReplication
creates the Continuous Access XP configuration definition file for RAID
Manager that is required to create copy pairs for Business Copy XP, Continuous Access XP, Continuous
Access XP Extension, and Snapshot XP.
Users with access to this command:
•
Yes: System Administrator, Storage Administrator
•
No: Guest, Local Guest
•
Restricted to permitted resources: Local System Administrator and Local Storage Administrator do not
have access range limitations.
NOTE:
Continuous Access XP Extension can be used for StorageWorks XP Disk Array. Snapshot XP can
be used for StorageWorks XP12000/XP10000.
Table 4-77
AddConfigFileForReplication Command Parameters
Parameter Name
Status
Description
groupname
Required (Method 1)
Group name used in the RAID Manager. You cannot specify a
name that begins with a hash mark (#) or hyphen (-). You can
use 31 or fewer characters.
When using Method 1, specify a group name that is specified in
the definition file.
pvolhostid
Required
Host ID for identifying the P-VOL.
When using Method 1, specify the host ID of the P-VOL in a
group specified in the definition file.
pvolinstancenum
Required (Method 1 or 2)
Instance number of the Continuous Access XP instance for
managing the P-VOL.
When using Method 1, specify the instance number of the P-
VOL of a group specified in the definition file.
pvolportnum
Required (Method 3)
Port number of the Continuous Access XP instance for
managing the P-VOL.
In Solaris™, specify an integer from 0 to 65535.
In AIX
®
, Windows
®
, HP-UX, and Linux
®
, specify an integer
from 1 to 65535.
This parameter is invalid when the pvolinstancenum is
specified.
svolhostid
Required
Host ID for identifying the S-VOL.
When using Method 1, specify the host ID of the S-VOL of a
group specified in the definition file.
svolinstancenum
Required (Method 1 or 2)
Instance number of the Continuous Access XP instance for
managing the S-VOL.
When using Method 1, specify the instance number of the S-
VOL of a group specified in the definition file.
svolportnum
Required (Method 3)
Port number of the Continuous Access XP instance for
managing the S-VOL.
In Solaris™, specify an integer from 0 to 65535.
In AIX
®
, Windows
®
, HP-UX, and Linux
®
, specify an integer
from 1 to 65535.
This parameter is invalid when the svolinstancenum is
specified.
pvolarraytype
Required
Model of the storage subsystem that includes the P-VOL.