Maintaining the switch, Installing dust covers in empty ports, Replacing an sfp transceiver – HP Cisco MDS 9124e Fabric Switch for BladeSystem c-Class User Manual

Page 30

Advertising
background image

Managing the Switch

30

The gateway address of the first switch should be set to whatever the gateway address is for the

subnet on which the first switch resides. See

Table 9

.

Maintaining the Switch

The Cisco MDS 9124e Switch does not require any regular physical maintenance. However, it is

critical that environmental conditions, described in ”

Environmental considerations

are met to help

prevent switch failure due to heat stress or improper air flow.

Installing dust covers in empty ports

The dust covers included in the Cisco MDS 9124e Switch shipping carton, (see

Figure 1

) must be

inserted in ports where SFPs are not installed. Installing dust covers ensures proper airflow and helps

reduce dust contamination of the switch.

Replacing an SFP transceiver

In some cases you might need to reinstall an SFP transceiver. To remove an SFP transceiver:

1.

Press and hold the cable release.

2.

Remove the cable from the transceiver.

3.

Pull the bail (wire handle) to release the transceiver.

4.

Grasp the bail, and gently but firmly pull the transceiver out of the port.

5.

Repeat this procedure for the remaining ports as required.

To install a replacement SFP:

1.

Make sure that the bail is in the unlocked position.

2.

Orient the SFP with the appropriate port. See

Figure 7

and

Table 10

.

Table 9

Connecting via a management station

Management

station

First switch

Second switch

Third switch

Ethernet

192.168.1.09

192.168.1.10

204.1.1.11

204.1.1.12

FCIP

192.168.65.09

192.168.65.10

192.168.65.11

192.168.65.12

Gateway

192.168.1.10

any, not self

192.168.1.10

192.168.1.10

Advertising