HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual

Page 10

Advertising
background image

Introduction 10

VCM is embedded on VC-Enet modules. You can access VCM through a web-based GUI or CLI. The

Onboard Administrator provides a web link to the Virtual Connect GUI. The CLI can be accessed remotely
through any SSH session or through the Onboard Administrator CLI.
The VC modules support the HP BladeSystem c7000 Enclosure, the HP BladeSystem c3000 Enclosure, and

all the server blades and networks contained within the enclosure. FlexFabric modules are only supported in

BladeSystem c7000 enclosures with G6 or newer server blades or Integrity i2 and i4 server blades with
Virtual Connect firmware v3.15 and later.
VC-Enet modules enable connectivity to data center Ethernet switches. VC-Enet modules can also be directly

connected to other types of devices, such as printers, laptops, rack servers, and network storage devices.
The VC-FC and FlexFabric modules enable connectivity of the enclosure to data center FC switches. Every FC
fabric is limited in the number of switches it can support, but the VC-FC modules do not appear as switches

to the FC fabric and do not count against FC fabric limits.
A basic Virtual Connect domain includes a single HP c-Class BladeSystem c7000 Enclosure for a total of 16

servers (or up to 32 servers if the double-dense option is enabled), or a single HP c-Class BladeSystem c3000
Enclosure for a total of 8 servers (or up to 16 servers if the double-dense option is enabled). For more

information on the double-dense option, see "Double-dense server bay option (on page

254

)" . Within the

domain, any server blade with the requisite LAN or SAN devices can access any LAN or SAN connected to

a VC module, and a server blade of a given processor type (Integrity or X86) can be used as a spare for any

server blade of the same processor type within the same enclosure, as long as the server has the requisite
number and type of connections. Using network access groups feature, the network administrator can clearly

define a separation of networks based on their allowed functionality and prevent the server administrator

from assigning specific network combinations in the same server profile.
By stacking (cabling) the VC-Enet modules together within the domain and connecting the VC-FC or
FlexFabric module FC uplinks on the same bay of all enclosures to the same FC switch, every server blade in

the domain can be configured to access any external network or fabric connection. With this configuration,

you can use VCM to deploy and migrate a server blade profile to any server in the Virtual Connect domain

without changing external LAN or SAN configurations.
Each version of VC is tested and supported with one or more SPPs. For a list of supported SPPs that must be

installed, see the VC release notes.

Advertising