Edit shared uplink set screen – HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual

Page 131

Advertising
background image

Virtual Connect networks 131

5.

To add labels to the network, type a label in the Labels field, and then press Enter. Labels are used as

text-based identifiers for the network within VCM. Each label can contain up to 24 characters,
excluding spaces. Each network can have up to 16 labels.

6.

To set the preferred or maximum connection speed, select the Advanced Network Settings checkbox.
To change these settings:

a.

Click the selection box.

b.

Select a setting (100Mb to 10Gb):

Set preferred connection speed. This value is the default speed for server profile connections

mapped to this network. The server administrator can override this setting on an individual

profile connection.

Set maximum connection speed. This value is the maximum speed for server profile connections

mapped to this network. This speed limits the maximum port speed from the server to the network
connection associated with the multiple networks.

7.

Click Apply. The associated network is now defined and available for use in creating server profiles.

After you add an FCoE network, the Add port menu now displays the bay information instead of a list of

enclosures.

Edit Shared Uplink Set screen

To access this screen, do one of the following:

Click the Edit link for a shared uplink set on the Shared Uplink Sets (External Connections) screen (on
page

134

).

Enter a shared uplink set name in the Find Configuration Items search field in the left navigation tree,
and then select the shared uplink set.