HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual

Page 125

Advertising
background image

Virtual Connect networks 125

In VC 3.30 and later, there is a limit of 1000 networks per VC domain. Additionally, the VLAN Capacity (on

page

97

) might place restrictions on the number of networks that can be added to a shared uplink set.

The following table describes the fields within the Define Shared Uplink Set screen.

Field name

Description

Ethernet Shared External Uplink
Set

Uplink Set Name

Descriptive name for the shared uplink set. Do not use spaces.

External Uplink Ports

Port

Enclosure, bay, and port number

Port Role

Displays whether the port is designated as primary or secondary. For shared

uplink sets with an associated FCoE network, the port role is N/A.

Port Status

Shows the link status, link speed, and connectivity of the port. If the port is
unlinked and no connectivity exists, the cause is displayed. For more

information about possible causes, see "Port status conditions (on page

264

)."

Connector Type

The type of connector on the port; for example, RJ-45

Connected To

If the individual port is connected to a switch that supports LLDP, the switch
LLDP system name or management IP address and switch port number

appear. A link is provided to obtain more information about the far-end

switch port.

PID

PID status icon (on or off) for the port

Speed/Duplex

Pull-down menu to specify the speed and duplex (where applicable) of the

uplink port. For shared uplink sets with an associated FCoE network, the

speed/duplex is Auto.

Action

Perform delete operations

Advertising