HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual

Page 208

Advertising
background image

Virtual Connect server profiles 208

Task

Action

Change the SAN fabric

connection

Click the pull-down arrow in the FC SAN name box.

Change or disable the port speed Click the pull-down arrow in the Port Speed box.
View Fibre Channel Boot
Parameters

Select the Fibre Channel Boot Parameters checkbox.

Enable Fibre Channel Boot on a

port

Select the Fibre Channel Boot Parameters checkbox. Click the pull-down

arrow in the SAN Boot box, and then select the boot order. Enter a valid Boot

Target name and LUN in the edit boxes.

Disable Fibre Channel Boot on a
port

Select the Fibre Channel Boot Parameters checkbox. Click the pull-down
arrow in the SAN Boot box, and then select Disabled.

Revert to BIOS settings for Fibre

Channel Boot

Select the Fibre Channel Boot Parameters checkbox. Click the pull-down

arrow in the SAN Boot box, and then select Use BIOS.

Change the profile bay
assignment

Select a new bay from the server pull-down menu at the bottom or the screen,
or select Unassigned.

Change the FCoE connection

Click the pull-down arrow in the FC SAN/FCoE Network Name box.

Change the FCoE port speed

Click the pull-down arrow in the Port Speed name box.

Clear unsaved changes on the
screen

Click Clear.

Save changes

Click Apply to save changes and remain on the edit screen, or Apply & Close
to save changes and return to the Server Profiles screen.

Cancel without saving changes Click Cancel.

Assigning a server profile with FCoE connections to an HP ProLiant
BL680c G7 Server Blade

To create a server profile with FCoE connections, and then assign it to an HP ProLiant BL680c G7 Server
Blade:

1.

Be sure that the HP ProLiant BL680c G7 Server Blade is installed correctly and powered down:

a.

Click Overview under Hardware in the left navigation tree to display the Enclosures View screen.

Advertising