CAUTION:

If an SIz S-VOL is in pending status and you execute an ICKDSF command for FlashCopy®

Mirror Version 2 , the ICKDSF job will end abnormally with CC=12 error. Table 7.22 describes how to

avoid that abnormal ending.

CAUTION:

You cannot create the FlashCopy® Mirror Version 2 pair since the data consistency of the

FlashCopy® Mirror Version 2 T-VOL will not be insured.

CAUTION:

If you create a FlashCopy® Mirror Version 2 pair with the FREEZE option when FlashCopy®

Mirror Version 2 S-VOL and TCz Synchronous R-VOL are shared, the results of FlashCopy® Mirror Version

2 operations and TCz Synchronous operations will be as follows:

When you use FlashCopy® Mirror Version 2 S-VOL as the TCz R-VOL, configure the system as follows.

Connect different hosts to main subsystem and remote subsystem, or connect the host of main subsystem

to both main and remote subsystem.

Use the fibre channel interface to connect main subsystem with remote subsystem.

TCzA

M-Vol

OK

OK

3

OK

R-Vol

No

1

No

1

OK

1

You cannot create the FlashCopy® Mirror Version 2 pair since the

data consistency of the FlashCopy® Mirror Version 2 T-VOL will not

be insured.

2

If you create a FlashCopy® Mirror Version 2 pair with the FREEZE

option when FlashCopy® Mirror Version 2 S-VOL and TCz

Synchronous R-VOL are shared, the results of FlashCopy® Mirror

Version 2 operations and TCz Synchronous operations will be as

follows:

Results of FlashCopy® Mirror Version 2 operations
When the status of TCz Synchronous pair is Suspend, the

command will end normally and you can create a FlashCopy®

Mirror Version 2 pair. However, when the status of TCz

Synchronous pair is either Duplex of Pending duplex, the

command will be rejected and you cannot create a FlashCopy®

Mirror Version 2 pair.

Results of TCz Synchronous operations
If a FlashCopy® Mirror Version 2 pair is created with the FREEZE

option, and when a TCz Synchronous R-VOL is in extended long

busy (ELB) status, the command to create or resume a pair will be

rejected. However, the command to suspend or delete a pair will

be executed normally.

3

If a TrueCopy for z/OS M-VOL is in pending status and you execute

an ICKDSF command for FlashCopy® Mirror Version 2 , the ICKDSF

job will end abnormally with CC=12 error. Table 7.22 describes how

to avoid that abnormal ending.

Table 53

Volume Share of FlashCopy® Mirror Version 2 S-VOL and TCz

Shared TCz Pair Volume

Status of TCz Pair

Duplex

Pending

Duplex

Suspend