Using a dfsms command, Ume123 – HP XP Business Copy Software User Manual

Page 123

Advertising
background image

ShadowImage for z/OS user guide 123

Table 56

Whether Reverse Restore Can be Performed When FlashCopy® Mirror Version 2 T-VOL is Used

as TCz Volume

NOTE:

This configuration differs from the system configuration that is used when IBM FlashCopy Version 2

and PPRC are used in conjunction.

Typically, when IBM FlashCopy Version 2 and PPRC are used in conjunction, you need a DFSMS

command, a TSO command, or a ICKDSF command when you use FlashCopy® Mirror Version 2 and

TCz.Note that the procedures differ depending on whether FlashCopy® Mirror Version 2 is used in

conjunction with TCz Synchronous or TCzA.

Using a DFSMS command

Use the following procedure when a DFSMS command is used and FlashCopy® Mirror Version 2 S-VOL

and TCzA R-VOL are shared. However, if the status of the TCz Synchronous pair is duplex, you need to use

a TSO , or a ICKDSF command. In addition, for details about the DFSMS to create a FlashCopy® Mirror

Version 2 pair, see

DFSM Command Supported by Compatible Mirroring for IBM FlashCopy Version 2

”.

1.

If you need to terminate the I/O operation on the volumes of TCz Synchronous pairs in order to

maintain the consistency of data, terminate the I/O operation.

2.

Suspend the TCzA pair. See the following example:
CSUSPEND DEVN(X dev#') PRIM(X ssid' cmd_param X cca X lss) SEC(X ssid' serial# X cca X lss)

3.

Set the TCzA R-VOL to online.
The host will be able to recognize the dataset on the TCzA R-VOL and figure out the extent for creating

a FlashCopy® Mirror Version 2 pair.

NOTE:

If the same host is connected to both TCzA M-VOL and R-VOL, the R-VOL label must be

rewritten.

4.

Use DFSMS to create a FlashCopy® Mirror Version 2 pair. See the following example:

COPY FULL INDYNAM(xxxxxx) OUTDYNAM(yyyyyy) FASTREP(REQ) FCCOPY

For details about the DFSMS to create a FlashCopy® Mirror Version 2 pair, see ”

DFSM Command

Supported by Compatible Mirroring for IBM FlashCopy Version 2

”.

5.

If

step 4

completes successfully, set the TCz Synchronous R-VOL to offline.

6.

Resynchronize the TCz Synchronous pair.

Using FlashCopy® Mirror Version 2 T-VOL and TrueCopy for z/OS M-VOL when shared

Follow the procedures below if FlashCopy® Mirror Version 2 T-VOL and TrueCopy for z/OS M-VOL are

shared.

1.

Suspend the TrueCopy for z/OS pair. See the following example:

CSUSPEND DEVN(X dev#') PTIM(X ssid' cmd_param X cca X lss) sec(X ssid' serial# X
cca X lss)

2.

Use DFSMS to create a FlashCopy® Mirror Version 2 pair. See the following example:

COPY DS(INCL(****.**)) INDYNAM (XXXXXX) OUTDYNAM(YYYYYY) FASTREP(REQ)
FCCOPY?FCTOPPRCPRIMARY

Shared TrueCopy for z/OS Pair

Volume

Status of TrueCopy for z/OS Pair

Duplex

Pending duplex

Suspend

TrueCopy for

z/OS

Synchronous

M-VOL

N/A

N/A

OK

TrueCopy for

z/OS

Asynchronous

M-VOL

N/A

N/A

OK

Advertising
This manual is related to the following products: