ShadowImage for the XP1024/XP128/XP12000/XP10000/SVS 200

SP-Pend The status becomes SP-Pend when the Steady

Split mode is selected for the split operation.

All S-VOL updates prior to the split command

are being copied to the T-VOL. When these

updates are complete, the split T-VOL is

identical to the state of the S-VOL when the

split started. The

XP1024/XP128/XP12000/XP10000/SVS

200 rejects writes for

SP-Pend T-VOLs.

S-VOL = PPRI-PNDG
T-VOL = PSEC-PNDG

Read/write.

Read/write

disabled.

V-Split

The status becomes V-Split when the Quick

Split mode is selected for the split operation.

Only the S-VOL differential data is being

copied to the T-VOL in background. The

XP1024/XP128/XP12000/XP10000/SVS

200 accepts writes for V-Split T-VOLs. The

V-Split pairs cannot be deleted.

S-VOL = PPRI-SUSP
T-VOL = SIMPLEX

Read/write.

Read/write,

can be varied

online.

Split

The

XP1024/XP128/XP12000/XP10000/SVS

200 stops performing update copy

operations for split pairs and starts accepting

write I/Os for split T-VOLs. The

XP1024/XP128/XP12000/XP10000/SVS

200 keeps track of all updates to the split

S-VOL and T-VOL so the pair can be resynced

accurately and quickly.

S-VOL = PPRI-SUSP
T-VOL = SIMPLEX

Read/write.

Read/write,

can be varied

online.

Resync

The

XP1024/XP128/XP12000/XP10000/SVS

200 does not accept write I/Os for resync

T-VOLs. When a split pair is resynchronized

in normal mode, only the S-VOL differential

data is copied to the T-VOL. When a

suspended pair is resynchronized, the entire

S-VOL is copied to the T-VOL. No update

copy operations are performed during resync

operation.

S-VOL = PPRI-PNDG
T-VOL = PSEC-PNDG

Read/write.

Read/write

disabled.

Resync-R The

XP1024/XP128/XP12000/XP10000/SVS

200 does not accept write I/Os for resync-r

T-VOLs or S-VOLs. When a split pair is

reverse resynchronized, the

XP1024/XP128/XP12000/XP10000/SVS

200 copies only the T-VOL differential data to

the S-VOL. The reverse resync cannot be

performed on suspended pairs. No update

copy operations are performed during

reverse resync or quick restore.

S-VOL = PPRI-PNDG
T-VOL = PSEC-PNDG

Read/write

disabled.

Read/write

disabled.

Suspend The

XP1024/XP128/XP12000/XP10000/SVS

200 does not perform update copy

operations to a suspended T-VOL. The

XP1024/XP128/XP12000/XP10000/SVS

200 marks the entire S-VOL track map as

differential data so the entire S-VOL is copied

to the T-VOL when the pair is resumed. Use

resync command to resume a suspended

pair. Reverse resync and quick restore cannot

be used to resume suspended pairs.

S-VOL = PPRI-SUSP
T-VOL = PSEC-SUSP

Read/write.

Read/write

disabled.

Table 8

ShadowImage for z/OS pair status (continued)

Status

Description

Host Status

S-VOL Access T-VOL Access