Resetting the Reserve Attribute

Use the Reset Reserve Attribute window to reset the reserve attribute for (that is, unreserve) the volume(s)

selected on the ShadowImage main window. To open the Reset Reserve Attribute window, select one or

more reserved simplex volumes in the Volume List box on the ShadowImage main window, right-click to

display the pop-up menu, and then click Change Reserve.

Figure 27

Reset Reserve Attribute window (unreserve)

The Reset Reserve Attribute window displays the reserved volume(s) that you selected on the ShadowImage

main window. The OK button resets the reserve attribute for reserved volume(s).

NOTE:

The Preset Volume List box on the ShadowImage main window displays the setting(s). The Cancel

button closes the Reset Reserve Attribute window without changing the settings. To apply the settings to the

XP1024/XP128/XP12000/XP10000/SVS 200, click Apply on the ShadowImage main window.

To unreserve one or more volumes (reset the reserve attribute):

1.

Verify that the volumes you want to unreserve are no longer assigned to SI390 pairs as T-VOLs. For

instructions on deleting SI390 pairs, see ”

Deleting ShadowImage Pairs

” on page 65.

2.

From the ShadowImage main window, click the CU image or LDEV in the Tree View box.

3.

Display reserved simplex volumes in the Volume List box. For example, to display reserved simplex

volumes, select the Reserved check box in the Display Filter window.

4.

Select the volume(s), right-click to display the pop-up menu, and then click Change Reserve. The Reset

Reserve Attribute window is displayed. If the Change Reserve command is not enabled, you selected

paired volumes. Select only reserved and unpaired volumes.

5.

From the Reset Reserve Attribute window, click the volume(s) you want to unreserve and then click OK.
The setting will be reflected in the Preset Volume List box on the ShadowImage main window.

6.

From the ShadowImage main window, click Apply.

7.

Verify that the settings are reflected in the XP1024/XP128/XP12000/XP10000/SVS 200. Check the

attribute by clicking Display Filter.