Command line 29

Item

Description

being specified should be associated with the same bay as the FC connection.
A blank string makes the FC connection unassigned.

Speed (optional)

The port speed of the FC SAN connection. Valid values include "Auto", "8Gb",

"4Gb", "2Gb", "1Gb", and "Disabled".
Speed restrictions:
For the HP 4Gb VC-FC Module and HP Virtual Connect 4Gb FC Module,

supported speed values include "Auto","1Gb","2Gb", and "4Gb", and
"Disabled". If the value is set to 8Gb, the speed is auto-negotiated by Virtual
Connect.

BootPriority

(optional)

Controls whether the FC HBA port is enabled for SAN boot and affects the BIOS
boot order. Valid values include "BIOS", "Primary", "Secondary", and
"Disabled".

BootPort (optional)

The target WWPN of the controller interface on the Fibre Channel storage
target. The port name is a 64-bit identifier in the format

NN:NN:NN:NN:NN:NN:NN:NN, where N is a hexadecimal number.

BootLun (optional)

The LUN of the volume used for SAN boot. Valid values include an integer from
0 to 255 or 16 hex digits (HP-UX only).

Examples

->set fc-connection MyProfile 1 Fabric=SAN_5

Changes the fabric of an FC SAN fabric connection

->set fc-connection RedProfile 2 Fabric=""

Sets a FC SAN fabric connection to "Unassigned"

->set fc-connection BlueProfile 1 Fabric=SAN_7

Changes the FC SAN fabric of an FC SAN connection

->set fc-connection BlueProfile 1 Speed=4Gb

Changes the port speed of an FC SAN connection

->set fc-connection BlueProfile 1 BootPriority=Primary

BootPort=50:06:0B:00:00:C2:62:00 BootLun=5

Changes the SAN boot priority and sets additional boot parameters

Item

Description

show fc-connection

Display the FC SAN connections associated with the server profiles.

Syntax

show fc-connection [<ConnectionID>]

Parameter

ConnectionID

(optional)

The ID of an existing FC SAN connection. The ID format is <ProfileName:Port>.

<ProfileName:*> can be used to display all the FC SAN connections of a
profile. '*' displays all the FC SAN connections existing in the domain.

Examples

->show fc-connection

Displays all FC SAN connections existing in the domain

->show fc-connection Profile1:*

Displays FC SAN connections of profile Profile1

->show fc-connection Profile1:1

Displays a specific FC SAN connection of profile Profile1

Advertising