background image

Command line 19

Item

Description

-> import enclosure 192.168.0.120

Imports a remote enclosure that is already discovered

Item

Description

remove enclosure

Remove a remote enclosure that has been imported into the domain. The local
enclosure cannot be removed from the domain using the remove enclosure

command.

Syntax

remove enclosure <EnclosureID | *>

Parameter

EnclosureID

(required)

The enclosure ID of the remote enclosure to be removed from the domain, where
"*" removes all the remote enclosures that exist in the domain. The enclosure IDs
can be identified for a particular enclosure by using the show enclosure

command. The local enclosure cannot be removed from the domain with this

command.

Examples

->remove enclosure encl

Removes a remote enclosure

->remove enclosure *

Removes all remote enclosures from the domain

Item

Description

show enclosure

Display all enclosures in the domain.

Syntax

show enclosure [<EnclosureID>|*]

Parameter

EnclosureID

(optional)

The ID of an enclosure in the domain. If specified, then only details for the
specified enclosure appear.

Examples

->show enclosure

Displays a summary listing of all enclosures

->show enclosure *

Displays detailed information for all enclosures

->show enclosure enc0

Displays detailed information for a specific enclosure

enet-connection

Manage Ethernet network connections.
Supported actions: add, help, remove, set, show

Item

Description

add enet-connection

Add a new Ethernet network connection to an existing server profile.
The maximum number of Ethernet connections that can be added to a
server profile is 128.

Syntax

add enet-connection <ProfileName>

[Network=<NetworkName>]

[PXE=<enabled|disabled|UseBios>]

[AddressType=<Factory-Default|User-Defined>]

[EthernetMAC=<MAC Address> iScsiMAC=<MAC Address>]

Advertising