Port status conditions – HP Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem User Manual

Page 181

Advertising
background image

Configuring the Virtual Connect domain using the CLI 181

Operation

Examples

Display general domain settings

>show domain

Display predefined address pools

>show domain addresspool

Display interconnect modules

•

Summary display

>show interconnect

•

Detailed display

>show interconnect *

•

Single module display

>show interconnect enc0:2

Display overall domain status

>show status

Display stacking link configuration and status >show stackinglink
Display the system log

>show systemlog

Display a list of servers in the domain

•

Summary display

>show server

•

Detailed display

>show server *

•

Single server display

>show server enc0:1

Display server profiles

•

Summary display

>show profile

•

Detailed display

>show profile *

•

Single profile display

>show profile MyProfile

Delete the domain configuration

>delete domain

Force a failover to the backup VC Manager

>reset vcm - failover

Power off server blades

>poweroff server enc0:2

>poweroff server *

Power on server blades

>poweron server enc0:1

>poweron server *

Reset a server blade

>reboot server enc0:4

>reboot server *

Unassign a server profile from a device bay

>unassign profile MyProfile

Modify Ethernet network connection properties >set enet-connection MyProfile 1 pxe=disabled
Modify FC fabric connections

>set fc-connection MyProfile 2 speed=auto

Port status conditions

If a port status is unlinked and no connectivity exists, one of the following appears:

•

Not Linked/E-Key—The port is not linked because of an electronic keying error. For example, a

mismatch in the type of technology exists between the server and module ports.

•

Not Logged In—The port is not logged in to the remote device.

•

Incompatible—The port is populated with an SFP module that does not match the usage assigned to the
port, such as a FC SFP connected to a port designated for Ethernet network traffic. A port that is not

assigned to a specific function is assumed to be designated for Ethernet network traffic.

Advertising