Command line 33

enet-vlan

Manage Ethernet VLAN configuration settings.
Supported actions: help, set, show

Item

Description

set enet-vlan

Modify general Ethernet VLAN configuration settings.

Syntax

set enet-vlan [-quiet][SharedServerVLanId=<true|false>]

[PrefSpeedType=<Auto|Custom>] [PrefSpeed=<speed>]

[MaxSpeedType=<Unrestricted|Custom>] [MaxSpeed=<speed>]

[VlanCapacity=<Legacy|Expanded>]

Option

quiet

This option suppresses user confirmation prompt, and is typically used in

automated scripting scenarios.

Properties

SharedServerVLanId

(optional)

Enables or disables the option to force server ports connected to multiple VC
Ethernet networks to use the same VLAN mappings as those used by

corresponding shared uplink sets. Valid values are "true" and "false".

Setting the value to "true" restricts the server network connections to be selected
from a single shared uplink, and the VLAN ID cannot be modified.

Setting the value to "false" enables you to select any VC Ethernet network for the

server Ethernet connections, and VLAN ID mappings can be modified to ensure
uniqueness.

PrefSpeedType

(optional)

The default connection speed for any Ethernet connection using multiple

networks. Valid values are "Auto" and "Custom". "Custom" enables you to

configure the preferred speed. The default value is "Auto".

PrefSpeed (required if

PrefSpeedType is

Custom)

The default connection speed for any Ethernet connection using multiple

networks. Valid values range from 100Mb to 10Gb in 100Mb increments.

MaxSpeedType

(optional)

The maximum connection speed for any Ethernet connection using multiple

networks. Valid values are "Unrestricted" and "Custom". "Custom" enables you
to configure the preferred speed. The default value is "Unrestricted".

MaxSpeed (required if

MaxSpeedType is

Custom)

The maximum connection speed for any Ethernet connection using multiple

networks. Valid values range from 100Mb to 10Gb in 100Mb increments.

VlanCapacity

(optional)

The VLAN capacity mode. Valid values are "Legacy" and "Expanded". The

default value is "Legacy".

"Legacy" mode allows up to 320 VLANs per module and 28 VLANs per server

connection.
"Expanded" mode allows up to 1000 VLANs per domain and 162 VLANs per

physical server port.

Examples

->set enet-vlan SharedServerVLanId=true

Enables SharedServerVLanId

->set enet-vlan PrefSpeedType=Custom PrefSpeed=500

MaxSpeedType=Custom MaxSpeed=2500

Sets the preferred connection speed for all connections using multiple networks to
500Mb, and the maximum connection speed to 2.5Gb

->set enet-vlan VlanCapacity=Expanded

Sets the VLAN capacity mode to Expanded to allow for larger network

configurations