fabric

Manage Fibre Channel SAN fabrics.
Supported actions: add, help, remove, set, show

Item

Description

add fabric

Add a new fabric to the domain. If the QoS type for the domain is set to

"CustomNoFcoe", then the fabric cannot include FCoE ports. If it does, the message
"cannot add fabric when QoS configuration type is CustomNoFCoE" appears. For

more information about setting the QoS type, see "qos (on page

90

)."

Syntax

add fabric <Name> Bay=<BayNum> Ports=<PortList>

[Type=<FabricAttach|DirectAttach>] [Speed=<Auto|2Gb|4Gb|8Gb>]

[LinkDist=<Auto|Manual>][PrefSpeedType=<Auto|Custom>]

[PrefSpeed=<100Mb-8Gb in 100Mb

steps>][MaxSpeedType=<UnRestricted|Custom>]

[MaxSpeed=<100Mb-8Gb in 100Mb steps>]

Parameter

Name (required)

A unique name is required when new fabric is added to the domain.

Properties

Bay (required)

The specific interconnect bay number with which the fabric is associated.

Ports (required) A list of one or more logical FC ports to be added to the fabric. Each port is specified

in the format "<port1>,<port2>,...", where "port" is the interconnect module port

number to be added to the fabric, for example "1, 2, 3, 4" (affects all modules within

a bay group).

For HP VC FlexFabric 10Gb/24-port Modules, port numbers 1, 2, 3, and 4
correspond to ports X1, X2, X3, and X4, respectively.

Type (optional)

The fabric type. "FabricAttach" is a SAN fabric. A "DirectAttach" fabric is directly

connected to a supported storage device. A "DirectAttach" fabric is only allowed for a
FlexFabric module. The default type is "FabricAttach".

Speed (optional) The port speed for the uplink ports in the fabric. Values include "Auto", "2Gb", "4Gb",

and "8Gb". The default port speed is "Auto".

Speed restrictions:

For the HP VC 4Gb FC Module, if the value is 8Gb, VCM translates the value to

"Auto", allowing the module to connect to the SAN switch at optimal speed.

For the HP VC 8Gb 24-Port FC Module, HP VC 8Gb 20-Port FC Module, and HP

VC FlexFabric 10Gb/24-port Module, values include "Auto", "2Gb", "4Gb", and
"8Gb".

LinkDist

(optional)

The login re-distribution scheme to use for load balancing. Values include "Auto" and

"Manual". The default login re-distribution is "Manual" for a "FabricAttach" fabric.

Login re-distribution is not supported for "DirectAttach" fabrics.
The HP VC 4Gb FC Module, HP VC 8Gb 20-Port FC Module, and HP VC 8Gb 24-Port

Module support only manual login redistribution. The HP VC FlexFabric 10Gb/24-port

Module supports both auto and manual login redistribution.

PrefSpeedType

(optional)

Preferred connection speed for any FCoE connection attached to this fabric. Values are

"Auto" and "Custom". "Custom" allows configuration of the preferred speed. The

default value is "Auto" and can be configured only if the fabric has uplink ports from
the FlexFabric interconnect module.

PrefSpeed

(required if

PrefSpeedType is

"Custom")

The preferred connection speed for any FCoE connection attached to this fabric. Values

range from: 100Mb-8Gb in 100Mb increments. This property can be configured only

if the fabric has uplink ports from the FlexFabric interconnect module.