Fc-connection – HP Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem User Manual

Page 39

Advertising
background image

Command line 39

Item

Description

Syntax

show fabric [<FabricName>|*]

Parameter

Name (optional)

Name of an existing fabric. Use “*” to display a detailed output of all fabrics in the VC
domain. If not specified, a summary output of all fabrics appears.

Examples

->show fabric

Displays a summary of all FC SAN fabrics

->show fabric *

Displays detailed information for all FC SAN fabrics

->show fabric SAN_5

Displays detailed information for a specific FC SAN fabric

fc-connection

Manage Fibre Channel SAN connections.
Supported actions: add, help, remove, set, show

Item

Description

add fc-connection

Add a new FC SAN connection to an existing server profile.
For more information, see "General requirements for adding FC or FCoE

connections (on page

178

)."

Syntax

add fc-connection <ProfileName> [Fabric=<FabricName>]

[Speed=<Auto|1Gb|2Gb|4Gb|8Gb|Disabled>]

[AddressType=<Factory-Default|User-Defined>]

[PortWWN=<WWN address>] [NodeWWN=<WWN address>]

Parameter

ProfileName (required) The name of an existing profile to which the new connection is added.
Properties

Fabric (optional)

The name of an existing fabric to associate with the connection. If the fabric

name is not specified, the connection is marked as “Unassigned” and
associated with a specific bay.

Speed (optional)

The port speed of the connection port. Values include "Auto", "1Gb", "2Gb",

"4Gb", "8Gb", and "Disabled". If not specified, the default port speed is set to

"Auto".
Speed restrictions:

For the HP VC 4Gb FC Module, supported speed values include

"Auto","1Gb","2Gb", "4Gb", and "Disabled". If the value is set to 8Gb, the
speed is auto-negotiated by VC.

AddressType (optional) The source of WWN address assignments used during the creation of the new

connection. If not specified, it defaults to the domain default. If "User-Defined" is

specified, then both a Port WWN and Node WWN must also be specified.
Values include "Factory-Default" and "User-Defined".

PortWWN (required if

AddressType is

User-Defined)

The user-defined Port WWN address to use for the connection. This property is

required if the AddressType specified is "User-Defined". The PortWWN must be
an unused WWN address.

NodeWWN (required if

AddressType is

User-Defined)

The user-defined Node WWN address to use for the connection. This property

is required if the AddressType specified is "User-Defined". The NodeWWN

must be an unused WWN address.

Examples