Fabric OS 5.x administrator guide 121

IOCP (and not in decimal values); the Domain IDs in the following example are for demonstration

purposes only.

Sample Resource Management Facility configuration file for mainframe

Resource management facility (RMF) is a performance management tool that measures selected areas of

system activity, including different views of the FICON channel. RMF presents data collected in the form of

System Management Facility (SMF) records. This data is essential for any kind of FICON channel

performance troubleshooting.
To obtain an RMF FICON director activity report, you must include the keyword

FCD

in the RMF

configuration file for the FICON director (this is generic for any FICON director). You must also define the

CUP port. In the following example, the keyword is boldfaced.

*------------------------------------------------------------------

* SilkWorm 24000 Domain_ID=61 (in hex)

*------------------------------------------------------------------

CNTLUNIT CUNUMBR=0D8,UNITADD=00,UNIT=2032,

PATH=(50,51),

LINK=(61FE,61FE)

IODEVICE ADDRESS=(0D8,1),CUNUMBR=0D8,UNIT=2032,STADET=Y,UNITADD=00

*---------------------------------------------------------------

*SilkWorm

12000

Domain_ID=22

(left

side

logical

switch

0

in

hex)

*---------------------------------------------------------------

CNTLUNIT CUNUMBR=0D9,UNITADD=00,UNIT=2032,

PATH=(8A,8B),

LINK=(22FE,22FE)

IODEVICE ADDRESS=(0D9,1),CUNUMBR=0D9,UNIT=2032,STADET=Y,UNITADD=00

*---------------------------------------------------------------

*

SilkWorm

12000

Domain_ID=23

(right

side

logical

switch

1

in

hex)

*---------------------------------------------------------------

*

CNTLUNIT CUNUMBR=0DA,UNITADD=00,UNIT=2032,

PATH=(92,93),

LINK=(23FE,23FE)

IODEVICE ADDRESS=(0DA,1),CUNUMBR=0DA,UNIT=2032,STADET=Y,UNITADD=00

*------------------------------------------------------------------

* SilkWorm 3900 Domain_ID=25 (in hex)

*------------------------------------------------------------------

*

CNTLUNIT CUNUMBR=0DB,UNITADD=00,UNIT=2032,

PATH=(5A,5B),

LINK=(25FE,25FE)

IODEVICE ADDRESS=(0DB,1),CUNUMBR=0DB,UNIT=2032,STADET=Y,UNITADD=00

*

*------------------------------------------------------------------