Enabling the tc feature, Displaying the status of the tc feature, Viewing the switch status policy threshold values – HP StorageWorks 2.128 SAN Director Switch User Manual

Page 36

Advertising
background image

36

Performing basic configuration tasks

Configuration file change from task

TC feature on

TC feature off

An SNMP-TRAP mode can also be enabled; see the

trackChangesHelp

command in the HP

StorageWorks Fabric OS 5.x command reference guide.
For troubleshooting information on the TC feature, see

Inaccurate information in the system message log

on page 161.

Enabling the TC feature

1.

Connect to the switch and log in as admin.

2.

Issue the

trackChangesSet 1

command to enable the TC feature:

A message is displayed, verifying that the TC feature is on:

switch:admin> trackchangesset 1

Committing configuration...done.

switch:admin>

The output from the TC feature is dumped to the system message log for the switch. Use the

errDump

or

errShow

command to view the log.

Items in the system message log created from the TC feature are labeled

TRCK

:

2004/08/24-08:45:43, [TRCK-1001], 212,, INFO, ras007, Successful login by user
admin.

Displaying the status of the TC feature

1.

Connect to the switch and log in as admin.

2.

Issue the

trackChangesShow

command.

The status of the TC feature is displayed as either on or off. The display tells whether the TC feature is

configured to send SNMP traps:

switch:admin> trackchangesshow

Track changes status: ON

Track changes generate SNMP-TRAP: NO

switch:admin>

Viewing the switch status policy threshold values

1.

Connect to the switch and log in as admin.

2.

Issue the

switchStatusPolicyShow

command.

Whenever there is a switch change, an error message is logged and an SNMP connUnitStatusChange

trap is sent.

For the 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/8V, SAN Switch 2/16V, SAN Switch 2/32,

Brocade 4Gb SAN Switch for HP p-Class BladeSystem, and SAN Switch 4/32: The output is similar to

the following:

switch:admin> switchstatuspolicyshow

The current overall switch status policy parameters:

Down Marginal

----------------------------------

PowerSupplies 2 1

Temperatures 2 1

Fans 2 1

Flash 0 1

MarginalPorts 5 2

FaultyPorts 2 1

MissingSFPs 2 1

switch:admin>