HP StorageWorks 2.128 SAN Director Switch User Manual
Page 226

226 Configuring the PID format
11.
Issue the command
cfgEnable [effective_zone_configuration]
.
For example:
cfgEnable my_zones
12.
Issue the
switchEnable
command. Enable the core switches first, and then the edges.
13.
Clean the
lvmtab
file by using the command
vgscan
.
14.
Change to
/dev
and untar the file that was tared in
.
For example:
tar –xf /tmp/jbod.tar
15.
Import the volume groups using
vgimport
.
The proper syntax is
vgimport –m mapfile path_to_volume_group
physical_volume_path
. For example:
vgimport –m /tmp/jbod_map /dev/jbod /dev/dsk/c64t8d0 /dev/dsk/c64t9d0
16.
Activate the volume groups using
vgchange
.
The proper syntax is
vgchange –a y path_to_volume_group
. For example:
vgexport –a y /dev/jbod
17.
If you are not using multipathing software, mount all devices again and restart I/O.
For example:
mount /mnt/jbod
18.
If you are using multipathing software, reenable the affected path.
The preceding steps do not clean up the results from
ioscan
. When viewing the output of
ioscan
,
notice that the original entry is still there, but now has a status of
NO_HW
. For example:
19.
To remove the original (outdated) entry, use the command
rmsf
(remove special file).
The proper syntax for this command is
rmsf –a –v path_to_device
. For example:
rmsf –a –v /dev/dsk/c65t8d0
20.
Validate that the entry has been removed by issuing the command
ioscan –funC disk
.
In this example, the
NO_HW
entry is no longer listed:
21.
Repeat this procedure for all fabrics.
22.
Issue the
switchEnable
command. Enable the core switches first, and then the edges.
# ioscan -funC disk
Class
I
H/W Path
Driver S/W State
H/W Type
Description
-------------------------------------------------------------------------------------
disk
0
0/0/1/1.2.0
adisk CLAIMED
DEVICE
SEAGATE ST39204LC
/dev/dsk/clt2d0 /dev/rdsk/c1t2d0
disk
1
0/0/2/1.2.0
adisk CLAIMED
DEVICE
HP
DVD-ROM 304
/dev/dsk/c3t2d0 /dev/rdsk/c3t2d0
disk
319 0/4/0/0.1.2.255.14.8.0
adisk CLAIMED
DEVICE
SEAGATE ST336605FC
/dev/dsk/c64t8d0 /dev/rdsk/c64t8d0
disk
320 0/4/0/0.1.18.255.14.8.0
adisk NO_HW
DEVICE
SEAGATE ST336605FC
/dev/dsk/c65t8d0 /dev/rdsk/c65t8d0
het46 (HP-50001)> ioscan -funC disk
Class
I
H/W Path
Driver S/W State
H/W Type
Description
-------------------------------------------------------------------------------------
disk
0
0/0/1/1.2.0
adisk CLAIMED
DEVICE
SEAGATE ST39204LC
/dev/dsk/clt2d0 /dev/rdsk/c1t2d0
disk
1
0/0/2/1.2.0
adisk CLAIMED
DEVICE
HP
DVD-ROM 304
/dev/dsk/c3t2d0 /dev/rdsk/c3t2d0
disk
319 0/4/0/0.1.2.255.14.8.0
adisk CLAIMED
DEVICE
SEAGATE ST336605FC
/dev/dsk/c64t8d0 /dev/rdsk/c64t8d0