Viewing equipment status, Displaying the status of the fans, Displaying the status of a power supply – HP StorageWorks 2.128 SAN Director Switch User Manual

Page 135

Advertising
background image

Fabric OS 5.x administrator guide 135

Viewing equipment status

You can display status for fans, power supply, and temperature.

NOTE:

The number of fans, power supply units, and temperature sensors depends on the switch type.

For detailed specifications on these components, see the SAN Switch installation guide for your switch

model. The specific output from the status commands varies, depending on the switch type.

Displaying the status of the fans

1.

Connect to the switch and log in as admin.

2.

Issue the

fanShow

command.

For example:

The possible status values are:

OK

: Fan is functioning correctly.

Absent

: Fan is not present.

Below minimum

: Fan is present but rotating too slowly or stopped.

Above minimum

: Fan is rotating too quickly.

Unknown

: An unknown fan unit is installed.

FAULTY

: Fan has exceeded hardware tolerance.

Displaying the status of a power supply

1.

Connect to the switch and log in as admin.

2.

Issue the

psShow

command.

For example:

frjt

Frames rejected with F_RJT

fbsy

Frames busied with F_BSY

Table 20

Port error summary description (continued)

Error type

Description

switch:admin> fanshow

Fan 1 is OK

speed is 7010 RPM

Fan 2 is OK

speed is 7180 RPM

Fan 3 is OK

speed is 7068 RPM

Fan 4 is OK

speed is 7116 RPM

Fan 5 is OK

speed is 7155 RPM

Fan 6 is OK

speed is 7001 RPM

switch:admin>

switch:admin> psshow

Power Supply #1 is OK

0335,FF2Z0007161,60-0000739-02, B,,DCJ3002-01P, B,FF2Z0007161

Power Supply #2 is faulty

0335,FF2Z0007176,60-0000739-02, B,,DCJ3002-01P, B,FF2Z0007176

switch:admin>