Executing the hp-ux procedure, Executing the hp–ux procedure – HP StorageWorks 2.128 SAN Director Switch User Manual

Page 225

Advertising
background image

Fabric OS 5.x administrator guide 225

For example:

10.

After all switches are updated to use the new PID format and reenabled, verify that the fabric has fully

reconverged (each switch sees the other switches).

11.

Issue the command

cfgEnable [active_zoning_config]

on one of the switches in the fabric to

update zoning to use the new PID form.

This does not change the definition of zones in the fabric, but merely causes the lowest level tables in

the zoning database to be updated with the new PID format setting. It is necessary to do this only once

per fabric; the zoning update propagates to all switches.
At this point, all switches in the fabric are operating in the new addressing mode.

Executing the HP–UX procedure

This procedure is not intended to be comprehensive. It provides a starting point from which a SAN

administrator could develop a site-specific procedure for a device that binds by PID, and cannot be

rebooted due to uptime requirements.

1.

Backup all data and verify the backups.

2.

If you are not using multipathing software, stop all I/O going to all volumes connected through the

switch/fabric to be updated.

3.

If you are not using multipathing software, unmount the volumes from their mount points using the

umount

command.

The proper syntax is

umount mount_point

. For example:

umount /mnt/jbod

4.

If you are using multipathing software, use that software to remove one fabric’s devices from its

configuration.

5.

Deactivate the appropriate volume groups using

vgchange

.

The proper syntax is

vgchange –a n path_to_volume_group

. For example:

vgchange –a n /dev/jbod

6.

Make a backup copy of the volume group directory using

tar

from within

/dev.

For example:

tar –cf /tmp/jbod.tar jbod

7.

Export the volume group using

vgexport

.

The proper syntax is

vgexport –m mapfile path_to_volume_group

. For example:

vgexport –m /tmp/jbod_map /dev/jbod

8.

Connect to each switch in the fabric.

9.

Issue the

switchDisable

command.

10.

Issue the

configure

command and change the Core PID format to 1.

switch:admin> switchdisable
switch:admin> configure
Configure...

Fabric parameters (yes, y, no, n): [no] yes
Domain: (1..239) [1]

R_A_TOV: (4000..120000) [10000]
E_D_TOV: (1000..5000) [2000]
Data field size: (256..2112) [2112]
Sequence Level Switching: (0..1) [0]
Disable Device Probing: (0..1) [0]
Suppress Class F Traffic: (0..1) [0]
SYNC IO mode: (0..1) [0]

Core Switch PID Format: (0..2) [0] 1

Per-frame Route Priority: (0..1) [0]
Long Distance Fabric: (0..1) [0]
BB credit: (1..27) [16]

Advertising