Battery replacement 98

Battery replacement

If the server blade no longer automatically displays the correct date and time, you may need to replace the

battery that provides power to the real-time clock. Under normal use, battery life is 5 to 10 years.

WARNING:

The computer contains an internal lithium manganese dioxide, a vanadium

pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not
properly handled. To reduce the risk of personal injury:

Do not attempt to recharge the battery.

Do not expose the battery to temperatures higher than 60°C (140°F).

Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.

Replace only with the spare designated for this product.

To remove the component:

1.

Power down the server blade (on page

14

).

2.

Remove the server blade (on page

15

).

3.

Remove the access panel (on page

16

).

4.

Identify the battery location ("

System board components

" on page

9

).

5.

Remove the battery.

IMPORTANT:

Replacing the system board battery resets the system ROM to its default

configuration. After replacing the battery, reconfigure the system through RBSU.

To replace the component, reverse the removal procedure.
For more information about battery replacement or proper disposal, contact an authorized reseller or an

authorized service provider.