54

HP 2012i Modular Smart Array user guide • January 2013

Data host IP addresses may not be set correctly

Controller enclosure host port addresses may not be set correctly on the data host

Cables between the controller enclosure and/or switches and/or data hosts may
not be connected correctly

Correct the issue, return to the Targets tab and click Refresh.

6. If two targets are configured, select the first target (controller module) and click

Log On.

7. On the Log On to Target dialog, set the following options:

a. For connectivity settings to persist across system reboots, check Automatically

Restore this Connection When the System Boots.

b. For fault-tolerant configurations, select Enable Multi-path.

c. Click Advanced to set connectivity settings as follows:

i. At the Local Adapter field, select Microsoft iSCSI Initiator from the drop-

down menu.

ii. At the Source IP field, select the IP address for the local data Ethernet port

that is on the same subnet as the first target portal (iSCSI host port) to which
you want the host to connect.

iii. At the Target Portal field, select the IP address for the iSCSI host port on the

target (controller module) to which you are connecting.

iv. Repeat the log on procedure (Step i through Step iii) to initiate connectivity for

the second target portal on the selected target.

8. To allow LUN access through all available ports during failover, change default

multipathing settings as follows:

a. On the Targets tab, select the target and click Details.

b. On the Devices tab of the Target Properties dialog, select the first device and

click Advanced.

c. On the MPIO tab of the Device Details dialog, select Round Robin from the Load

Balance Policy drop-down menu and click OK.

d. Repeat Step b and Step c for all devices listed.

9. Repeat tasks in Step 6, Step 7, and Step 8 for the second target.