Snapshot Resource Volumes

•

Fibre Channel Switch Information

•

RAID Array Storage Systems

•

External Storage Connections

Storage System Information

Select the Storage System Information entry from the Mass Storage submenu to display the following
information about an external array storage system:

Storage System Chassis Information

•

Model displays the type of storage system chassis.

•

Name displays the user-defined name (or serial number, if preferred) of this storage system
chassis.

•

Connection Type displays the type of connection between the server and the box. The following
values are possible:

◦

Fibre Attached - This chassis is attached to the server through Fibre Channel.

◦

SCSI Attached - This chassis is attached to the server with a SCSI cable.

◦

SAS Attached - This chassis is attached to the server with a SAS cable.

◦

Unknown - The Storage Agents are unable to determine the type of connection.

•

Serial Number displays the storage system chassis serial number, which is normally displayed
on the front panel. Use this information for identification purposes.

•

IO Slots displays whether an array controller is installed. If an array controller is installed then
the type of array controller is displayed. The following values are possible:

◦

Not Installed - An array controller is not installed in the IO slot.

◦

Fibre Array - A Fibre Channel array controller is installed in the IO slot.

◦

SCSI Array - A SCSI array controller is installed in the IO slot.

◦

Unknown Array - The Storage Agents cannot identify the type of array controller installed
in the IO slot. The Storage Agents may need to be upgraded to a later version.

◦

Unknown - The Storage Agents are unable to determine what is installed in the IO slot.

•

IO Module Type displays the storage system chassis SCSI I/O module type that is installed.
The following values are possible:

◦

2 Port Ultra3 SCSI Module - A 2 Port Ultra3 SCSI I/O Module is installed.

◦

4 Port Shared Storage Module - A 4 Port Shared Storage Module for the Smart Array
Cluster Storage is installed.

◦

4 Port - Upgrade Firmware - A 4-Port Shared Storage Module for the Smart Array Cluster
Storage is installed, but the current controller firmware does not support it. The controller
firmware must be upgraded.

◦

2 Port Ultra320 SCSI Module - A 2 Port Ultra320 SCSI I/O Module is installed.

◦

4 Port Ultra320 SCSI Module - A 4 Port Ultra320 SCSI I/O Module is installed.