Array controller information – HP Insight Management Agents User Manual

Page 71

Advertising
background image

Array Controller Information

This section displays the following information about array controllers that are installed in a storage
system.

•

Model displays the model name of the controller card.

•

Firmware Version displays the version of the controller's firmware.

•

Serial Number displays the serial number of the controller. Use this information for identification
purposes.

•

Product Revision displays the product revision of the controller. Use this value to further identify
a particular revision of the controller model.

•

World Wide Port Name displays the unique Fibre Channel port name for the controller. Use
this value to further identify a particular controller.

•

World Wide Node Name displays the unique Fibre Channel node name for the controller.
Use this value to further identify a particular controller.

•

Rebuild Priority displays the logical drive rebuild priority of the controller. The following values
are valid:

◦

Low - indicates the rebuild priority is low.

◦

Medium - indicates the rebuild priority is medium.

◦

High - indicates the rebuild priority is high.

◦

Unknown - indicates that the rebuild priority is not recognized. You may need to upgrade
the Storage Agents.

•

Expand Priority displays the logical drive expand priority of the controller. The following values
are valid:

◦

Low - indicates the expand priority is low.

◦

Medium - indicates the expand priority is medium.

◦

High - indicates the expand priority is high.

◦

Unknown - indicates that the expand priority is not recognized. You may need to upgrade
the Storage Agents.

•

Controller Status displays the status of the controller hardware. The following values are valid:

OK - The controller is operating normally.

◦

◦

Failed - The controller has failed and is no longer operating.

◦

Offline - The controller is offline.

◦

Redundant Path Offline - There are multiple connection paths to this controller. At least
one connection path is available and at least one connection path is not available.

◦

Unknown - Indicates that the Storage Agents are unable to determine the status of the
controller. You may need to upgrade the Storage Agents.

•

Current Role displays the array controller's current role for duplexed array controllers. The
following values are valid:

◦

Not Duplexed - This array controller is not duplexed.

◦

Active - This duplexed array controller is the active controller.

Storage agent

71

Advertising