Operational restrictions, Restrictions on lun manager operations, Table 15 lun manager operation restrictions – HP StorageWorks XP Remote Web Console Software User Manual

Page 50: 15 lun manager operation restrictions

Advertising
background image

50

LUN Manager for the XP1024/XP128

Table 14

shows the relationship between the combinations of port settings and the connection results.

Irrespective of whether a host is configured for port authentication using CHAP, the connection results are

as follows, unless otherwise noted.

.

For additional information on user authentication, see ”

User authentication (iSCSI environments only)

” on

page 23.

Operational restrictions

The success of some LUN Manager activities depends on the status of the security switch and whether I/O

is active or inactive to the port or LUN. The following tables describe those restrictions.

NOTE:

If you attempt to apply a large number of the settings in the LUN Manager panels in a single session,

the XP1024/XP128 might be unable to continue processing. It is recommended that you apply no

more than 1,000 settings per session. Note that a large number of settings are likely to be applied

when you define alternate paths (see ”

Defining alternate paths

” on page 37), even though only two

commands are required to define alternate paths.

Do not remove LU paths (see

Changing or viewing LU path settings

” on page 34) when the hosts are

performing I/O processing.

Do not remove LUN security (see

Applying and removing LUN security

” on page 39) when the hosts

are performing I/O processing.

Restrictions on LUN Manager operations

Table 14

Combinations of iSCSI port settings and connection results

Port settings

Connection results

Authentication:

at port

User information

registered on host?

Enable

authentication

ON

Yes

Selected

Connected if the host authentication was
successful (processing will continue to port
authentication)

1

1. If a host is not configured for port authentication using CHAP, the host cannot connect to the disk array.

ON

Yes

Not selected

Connected without host authentication

ON

No

2

2. ---: This item does not affect the connection results, or cannot be specified.

Authentication failed to be authenticated and

cannot be connected

OFF

Connected without host authenticati

on

3

3. If a host uses Microsoft iSCSI Initiator and is configured for port authentication using CHAP, host authentication will fail. To

allow such a host to connect to the port without authentication, do not configure it for CHAP port authentication.

Table 15

LUN Manager operation restrictions

Activity

Security switch OFF

Security switch ON

Host group 0

Host group

01-7F

Host group 0

Host group

01-7F

Setting the LUN

Security Switch

ON

With active

I/O on port

Permitted with

confirmation

message

Invalid operation

Invalid operation

With no active

I/O on port

Advertising
This manual is related to the following products: