Redundancy (vraid) levels, Snapclones, Redundancy (vraid) levels snapclones – HP P6000 Continuous Access Software User Manual

Page 269: Redundancy level (vraid), Redundancy level

Advertising
background image

◦

Must be in a normal operational state. See resources

Operational states

.

◦

Must use mirrored cache. See virtual disks

Cache policies

.

◦

Must have the same presentation status as other virtual disks in the DR group. With some
versions of controller software, the virtual disk must be presented to a host. See storage
systems

Controller software features - remote replication

. See also virtual disks

Presentation

.

Redundancy (Vraid) levels

Vraid is an HP term for implementing RAID storage (Redundant Array of Independent Disks). Virtual
disks with HP Vraid use three key RAID methods: data striping, data mirroring, and parity error
checking.

Data striping improves speed by performing virtual disk I/O with an entire group of physical disks
at the same time. Data mirroring provides data redundancy by storing data and a copy of the
data. Parity error checking provides automatic detection and correction if corruption of a physical
disk occurs. Unlike traditional RAID, all HP P6000 Vraid levels distribute data across all available
physical disks.

The redundancy (Vraid) level for a virtual disk determines the virtual disk's availability (data
protection) and influences its I/O performance. Once a virtual disk is created, its Vraid type cannot
be changed.

Vraid levels are:

•

Vraid0. Vraid0 (striping) and is optimized for speed and disk space utilization but does not
provide any redundancy.

IMPORTANT:

HP does not recommend using Vraid0 when high availability is required.

•

Vraid1. Vraid1 (striping with mirroring) is optimized for speed and high data redundancy. A
Vraid1 virtual disk can automatically recover (reconstruct) from the failure of one physical
disk. Vraid1 uses about twice the physical disk space than Vraid0.

•

Vraid5. Vraid5 (striping with parity) is optimized for speed, disk space utilization, and moderate
redundancy. A Vraid5 virtual disk can automatically recover (reconstruct) from the failure of
one physical disk. Vraid5 uses about 20% more physical disk space than Vraid0.

•

Vraid6. Vraid6 (striping with dual parity) is optimized for speed and the highest redundancy.
A Vraid6 virtual disk can automatically recover (reconstruct) from the concurrent failure of two
physical disks. Vraid6 uses about 33% more physical disk space than Vraid0. Vraid6 support
is dependent on the controller software version. See the HP P6000 Enterprise Virtual Array
Compatibility Reference
.

Disk groups with large physical disks

IMPORTANT:

If a disk group includes large physical disks (for example, 1 TB or larger), HP

recommends using Vraid6 for the virtual disks.

The recovery (reconstruction) time for virtual disks increases with the size of the physical disks in
the disk group. With Vraid1 or Vraid5, a second physical disk failure during the longer recovery
time could prevent a complete recovery. The use of Vraid6 reduces the risk.

Snapclones

Snapclone replication instantly creates an independent, point-in-time copy of a virtual disk. The
copy begins as a fully allocated snapshot, and then automatically becomes an independent virtual
disk. The copy is called a snapclone. See also virtual disks

Snapclone FAQ

and

Snapclone

guidelines

.

Virtual disk concepts 269