Understanding the Policy Advisor Analysis Process

3PAR Policy Advisor User’s Guide

4

Analyze the results displayed by the Policy Advisor. You should carefully review the

suggestions before running any suggested tuning operations.

5

Run the Dynamic Optimization tuning commands suggested by the Policy Advisor.

See

Chapter 2, Overview

for more information about when the Policy Advisor for Dynamic

Optimization should be run.

4.6 Understanding the Policy Advisor Analysis Process

The Policy Advisor script has two phases of operation.

Analysis Phase

Checks for failed and degraded Physical Disks (PDs). You should correct any reported faults

before tuning.

Excludes virtual volumes with tuning operations in progress.

Excludes virtual volumes split between CPGs, virtual volumes split between CPGs must be

tuned manually.

Generating Tuning Suggestions Phase

Simulates tuning operations on specified virtual volumes to verify they will work.

Presents tuning suggestions.

For specified virtual volumes that provision space directly from Logical Disks (LD):

Analyzes layouts for specified virtual volumes. Reports any virtual volumes for which the

layout can be improved.

If RAID type, set size, HA etc. specified, note virtual volumes not meeting the

parameters.

For specified virtual volumes that belong to a CPG:

Analyzes virtual volume to LD mappings. Analyzes the LD layout to see if it can be

improved. If the layout can be improved, reports all virtual volumes that belong to

inefficiently laid out LDs.

NOTE: Use the

Ctrl-C

command to cancel the Policy Advisor script.