1 physical disk analysis, Physical disk analysis, 1 failed and degraded physical disks – HP 3PAR Policy Manager Software User Manual

Page 26

Advertising
background image

4.10

Understanding the Policy Advisor Analysis Process

3PAR Policy Advisor User’s Guide

4.6.1 Physical Disk Analysis

The analysis of physical disks has two functions. Failed and degraded disks in the system are

identified so that you can resolve any issues, and a summary report of physical disks in the

system is created for your information. For more information about physical disk analysis

requirements and restrictions, see

Requirements and Restrictions

on page 4.2. For detailed

information about the InForm OS CLI commands, see the InForm OS Command Line Interface

Reference and InForm CLI Help.

4.6.1.1 Failed and Degraded Physical Disks

You should clear or repair any faults discovered before proceeding with the tuning operations

because analysis and tuning operations do not include failed and degraded disks. This may

result in an inefficient layout and the need to re-tune the system after the disks are repaired or

replaced.

Sample output from an InServ Storage Server with failed and degraded disks is shown below:

./PolicyAdvisor.tcl

-------------------------------------------------------------

3PAR, Inc. InForm(tm) Policy Advisor for Dynamic Optimization

-------------------------------------------------------------

Warning: 4 Physical Disks (PDs) are not available:

Id CagePos Type -State-- -------Detailed_State--------

2 0:0:2 FC degraded not_available_for_allocations

4 0:1:0 FC degraded not_available_for_allocations

5 0:1:1 FC degraded not_available_for_allocations

6 0:1:2 FC degraded not_available_for_allocations

We recommend that you fix the problem above before proceeding

Continue without fixing?

select q=quit y=yes n=no: