HP 3PAR Policy Manager Software User Manual

Page 35

Advertising
background image

4.19

Analyzing the Policy Advisor Results for RAID Level Changes

3PAR Policy Advisor User’s Guide

The CPG logical disk groupings are displayed showing both the current and possible layout

information:

------------------

CPG to LD Analysis

------------------

Tune ----------Current---------- ---------Possible----------

LD? CPG LDIds Space TotalCh LD# Disks MinCh MaxCh AvgCh LD# Disks MinCh MaxCh AvgCh

Yes c1 9 USR 80 1 16 5 5 2 4 32 2 3 2

The Policy Advisor identified 16 physical disks used to create the LD associated with this virtual

volume. If the virtual volume is tuned again, it would occupy 32 physical disks.

Total of 1 set of LDs analyzed

Name -----------Criteria------------ -SkipReason- --------TuneCmd--------

vv1 LDs occupy 16 PDs, potential 32 tunevv usr_cpg c1 -f vv1

The suggested CLI commands you should run are displayed:

---------------------------

Suggested tune command list

---------------------------

tunevv usr_cpg c1 -f vv1

Total of 1 tune command to run

For a complete list of options available for the

tunevv

command, see the InForm OS

Command Line Interface Reference and InForm CLI Help.

4.8 Analyzing the Policy Advisor Results for RAID Level Changes

If you want to change the RAID level of virtual volumes, running the Policy Advisor produces

results similar to the following example. During the analysis phase ellipses are displayed to

show the script is progressing. If there are any system issues, the script displays the information

before running.

Advertising
This manual is related to the following products: