Installing and Configuring the Tape Drive for the
NonStop NS-Series Server

M8609A Tabletop Tape Drive Installation and User’s Guide546013-002

2 -4

Installation

5. Connect the other end of the fiber-optic cable to the Fibre Channel ServerNet

adapter (FCSA) on the NonStop NS-series server. See

Figure 2-4

for the location.

6. Attach the power cord to the tape drive’s AC power receptacle (see

Figure 2-3

on

page 2-3 for the location) and then plug the other end into an AC power outlet.

7. Toggle the power switch to the on position from the rear of the unit. See

Figure 2-3

on page 2-3 for the location.

Figure 2-4. View of Two FCSAs at Rear of Server

Note. The tape drive does not have protection against lightning surges. Customers in high-risk
areas should use external surge protection rated for use in their location and be able to handle
the power demand of the tape drive.

Fiber-Optic Cables