System maintenance switch

Position

Default

Function

S1

Off

Off = iLO security is enabled.

On = iLO security is disabled.

S2

Off

Off = System configuration can be
changed.

On = System configuration is locked.

S3

Off

Reserved

S4

Off

Reserved

S5

Off

Off = Power-on password is enabled.
On = Power-on password is disabled.

S6

Off

Off = No function
On = ROM reads system configuration
as invalid.

S7

—

Reserved

S8

—

Reserved

S9

—

Off = PCIe 64-bit BAR function (large
BAR) is disabled.
On = PCIe 64-bit BAR function (large

BAR) is enabled.

S10

—

Reserved

S11

—

Reserved

S12

—

Reserved

To access the redundant ROM, set S1, S5, and S6 to on.
When the system maintenance switch position 6 is set to the On position, the system is prepared to erase all
system configuration settings from both CMOS and NVRAM.

CAUTION:

Clearing CMOS and/or NVRAM deletes configuration information. Be sure to

properly configure the server or data loss could occur.

Drive bay numbering

•

Drive bay numbering for four 1U nodes
In an 8-drive bay LFF drive configuration, drives are numbered from top to bottom in each box.

o

Drives in the first box correspond to node 1.

o

Drives in the second box correspond to node 2.

o

Drives in the third box correspond to node 3.

o

Drives in the fourth box correspond to node 4.

CAUTION:

To prevent improper cooling and thermal damage, do not operate the chassis unless

all bays are populated with a component or a blank.