Hardware options installation 35

CAUTION: After the server blade is powered down, wait 15 seconds and then check the amber LED

before removing the battery from the cache module. If the amber LED flashes after 15 seconds, do not

remove the battery from the cache module. The cache module is backing up data, and data is lost if the

battery is detached before the LED is extinguished.

IMPORTANT: The battery pack might have a low charge when installed. In this case, a POST error

message is displayed when the server blade is powered up, indicating that the battery pack is temporarily

disabled. No action is necessary on your part. The internal circuitry automatically recharges the batteries

and enables the battery pack. This process might take up to four hours. During this time, the cache module
functions properly, but without the performance advantage of the battery pack.

NOTE: The data protection and the time limit also apply if a power outage occurs. When power is restored

to the system, an initialization process writes the preserved data to the hard drives.

To install the component:

1.

Power down the server blade (on page

13

).

2.

Remove the server blade (on page

14

).

3.

Remove the access panel (on page

14

).

4.

Remove mezzanine card 3, if necessary, .

5.

Remove the existing Smart Array E200i cache module.