Setting the priority of ports on disk arrays, Figure 12 add wwn dialog box, 12 add wwn dialog box – HP StorageWorks XP Remote Web Console Software User Manual

Page 22: Connections

Advertising
background image

22

Performance Control XP

Setting the priority of ports on disk arrays

If a one-to-one connection is established between HBAs and ports, you must measure traffic between

high-priority HBAs and prioritized ports and between low-priority HBAs and non-prioritized ports.

1.

Start Performance Control XP (”

Starting Performance Control XP

” on page 18). The Performance

Control pane appears.

2.

Click Port.

3.

Select All from the list at the top right corner of the pane.

4.

Right-click a high-priority port, and select Non-Prio. ->> Prioritized. If there is more than one

high-priority port, repeat this operation.
Prio. is displayed in the Attribute column.

5.

Right-click a low-priority port, and select Prio. ->> Non-Prio. If there is more than one low-priority port,

repeat this operation.
Non-Prio. is displayed in the Attribute column.

6.

Click Apply. The settings on the pane are applied to the disk array.

7.

For instructions on measuring traffic (I/O and transfer rates), see the HP StorageWorks Auto LUN XP

User Guide for the specific disk array.

Measuring traffic between host bus adapters and ports for many-to-many connections

If a many-to-many connection is established between host bus adapters (HBAs) and ports, you must

measure traffic between each HBA and the port to which the HBA is connected.

1.

Start Performance Control XP (”

Starting Performance Control XP

” on page 18). The Performance

Control pane appears.

2.

Click WWN.

3.

Select All from the list at the top right corner of the pane.

4.

In the upper-left tree view, double-click a port.

5.

Double-click Non-Monitor below the specified port. Host adapters that are not being monitored are

displayed under Non-Monitor.

6.

Right-click Monitor, and select Add WWN to display the Add WWN dialog box where you can add a

prioritized or non-prioritized WWN to the Monitor branch.

Figure 12

Add WWN dialog box

7.

Specify the WWN and PFC name (16-character maximum), and click OK. The specified WWN

appears below Monitor.

NOTE:

To simplify managing HBAs, use the same name for the PFC name and HBA nickname.

NOTE:

Performance Control XP does not monitor HBAs below Non-Monitor. You cannot set upper

limits and thresholds to HBAs that are not monitored. To move an HBA (WWN) from Monitor to

Non-Monitor, select an HBA from below Monitor, right-click Monitor, and select Delete WWN. You

can monitor up to 32 HBAs (WWNs) for each port.