Performance Control Export Tool

The following is an example of information that the show subcommand outputs:

Short Range

indicates the storing period and gathering interval of the monitoring data stored in

short range. Long Range indicates those of the monitoring data stored in long range. In the above

example, the monitoring data in short range is stored every 1 minute in the term of 1:00-15:00 on

Oct. 1, 2004. Also, the monitoring data in long range is stored every 15 minutes in the term of Sep. 1,

2004, 0:00 through Oct. 1, 2004, 15:00. When you run the Export Tool, you can export monitoring

data within these periods into files.
All the monitoring items are stored in short range, but a part of monitoring items is stored in both the

short range and long range. For details on monitoring items that can be stored in long range, see ”

The

longrange subcommand

” on page 71.

The use of the show subcommand is not mandatory, but you are recommended to include the show

subcommand in your command file. If an error occurs when you run the Export Tool, you might be able

to find the error cause by checking the log file for information issued by the show subcommand. For

detailed information about the show subcommand, refer to

The show subcommand

” on page 57.

group PhyPG Long

and group RemoteCopy

This subcommand specifies the type of data that you want to export. Specify an operand following
group

to define the type of data to be exported. Basically, monitoring data stored in short range is

exported, but you can export monitoring data stored in long range when you specify some of the

operands.
The group PhyPG Long subcommand in

Figure 18

specifies to export usage statistics about parity

groups in long range. Also, the group RemoteCopy subcommand specifies to export statistics about

remote copy operations by Continuous Access XP and TrueCopy for z/OS in short range. You can

describe multiple lines of the group subcommand to export multiple monitoring items at the same time.
For detailed information about the group subcommand, see

The group subcommand

” on page 58.

shortrange 200410010850:200410010910

, and

longrange 200409301430:200410011430

, and

remotecopyrange 200409301430:200410011430

The shortrange and longrange subcommands specify the term of monitoring data to be exported.

Use these subcommands when you want to narrow the export-target term within the stored data. You

can specify both the shortrange and longrange subcommands at the same time. The difference

between these subcommands is as follows:
• The shortrange subcommand is valid for monitoring data in short range. You can use this

subcommand to narrow the export-target term for all the monitoring items you can specify by the
group

subcommand.

Specify a term within Short Range From XXX To XXX which is output by the show

subcommand.

• The longrange subcommand is valid for monitoring data in long range. You can use this

subcommand only when you specify the PhyPG, PhyLDEV, PhyProc, or PhyCSW operand with

the Long option in the group subcommand. (The items that can be saved by these operands are

the monitoring data displayed in the Physical tab of the Auto LUN XP pane with selecting
longrange

.)

Specify a term within Long Range From XXX To XXX which is output by the show

subcommand.

In

Figure 18

, the shortrange 200410010850:200410010910 subcommand specifies the term

8:50-9:10 on Oct. 1, 2004. This subcommand is applied to the group RemoteCopy subcommand

in this example. When you run the Export Tool, it will export the statistics about remote copy operations

by Continuous Access XP and TrueCopy for z/OS in the term specified by the shortrange

subcommand.
Also, in

Figure 18

, the longrange 200409301430:200410011430 subcommand specifies the

term from Sep. 30, 2004, 14:30 to Oct. 1, 2004, 14:30. This subcommand is applied to the group

Short Range From: 2004/10/01 01:00 - To: 2004/10/01 15:00Interval : 1min

Long Range From: 2004/09/01 00:00 - To: 2004/10/01 15:00Interval : 15min

Remote Copy From: 2004/09/30 00:00 - To: 2004/10/01 15:00