4 Removing and replacing parts

This chapter provides information for the removal and replacement of each expansion module and
field replaceable unit (FRU).

CAUTION:

Components within the library contain static-sensitive parts. Use appropriate ESD

precautions, including the use of a grounding strap, when performing service inside the library.

Interface Manager card

342213-001, 393531-001 or 480240-001

Part Number

Bottom slot in the base-module card cage

Location

Contains six Ethernet connections to the library robotics controller,
four interface controllers, and the SAN; two 3-pin serial ports;
status, activity, and error LEDs

Characteristics

Manages the interface controllers in order to monitor and manage
the library

Function

342213-001 or 393531-001

Illustration

480240-001

Required tools

#1 Phillips screwdriver

Interface Manager card 342213-001 or 393531-001

This section explains how to replace the 342213-001 or 393531-001 Interface Manager card
installed in an EML E-Series tape library. These versions of the Interface Manager card contain a
label with the part number AS#340252-001 or AS#340252-002 and have an AUX port next to
the serial port.

Removing the Interface Manager card 342213-001 or 393531-001

1.

Use your backup software to stop all library activity and make sure the picker is empty.

2.

Turn off the power to the library.

3.

Identify the Interface Manager card. It is located in the bottom slot in the card cage in the
base module.

4.

Label the cables or write a note that shows the locations of all the cables plugged into the
Interface Manager card to make it easier to reconnect them later.

5.

Unplug all cables from the Interface Manager card.

64

Removing and replacing parts