Installing the NetServer in an HP Systems Rack

93

Hewlett-Packard Systems Rack template

Tape or a marker pen to mark mounting locations

Installing the Slides

The following steps and illustrations describe how install slides for mounting a
NetServer.

Marking the Columns

Mark the mounting location of the NetServer and mounting holes on each
column of the rack as described (see Figure A-2).

NOTE

The EIA unit marks are stamped in the sheet metal of the
columns. tYiou can use the rack template to mark the correct
holes for mounting (on all four columns).

Marking Front Columns

Mark the slide mounting holes on the front columns.

1. Mark the base line (bottom) of the NetServer at an EIA unit mark on the

column.

2. Hold the bottom of the rack template at the base line. Mark the top of

NetServer (8 EIA units counted up from the base line).

3. Mark the slide screw mounting holes (holes 20 and 22 counted up from

the base line).

4. Mark the second front column by repeating steps 1 through 3 and .

Marking Rear Columns

Mark the slide mounting holes on the inside faces of the rear columns.

1. Mark the base line (bottom) of the NetServer at an EIA unit mark on the

column.

2. Hold the bottom of the rack template at the base line. Mark the top of

NetServer (8 EIA units counted up from the base line).

3. Mark the slide mounting hole (hole 21 counted up from the base line).