Correcting error conditions

Correcting an error may require you to perform a specific set of actions. Your authorized-HP service

representative can help you determine the corrective action to take.

Disk drive error conditions

The format of a disk drive error condition report is 0.1.en.ec, where:

•

0.1. identifies a disk problem.

•

en. identifies the affected disk drive bay number.
A direct correlation exists between the disk drive element number and the bay number.
The bays are numbered sequentially 1 through 14 from left to right.

•

ec is the error code.

Table 21 Disk drive error conditions

Error

condition

Severity

Description

Actions

0.1.en.01

Critical

Drive configuration or drive link rate

error:
The drive in bay en is either not

FC-compatible or is unable to operate

at the link rate established by the I/O

module.

1.

If the drive is not

FC-compatible, replace it

with a FC-compatible drive or

a drive blank.

2.

Replace the drive with a FC

drive capable of operating at

a link rate established by the

I/O module.

0.1.en.02

Information

Drive is missing from bay en.

1.

If the bay is empty, install a

drive or a drive blank.

2.

Reseat the drive to ensure that

it is properly installed.

3.

Install a replacement drive or

drive blank.

0.1.en.03

Information

Drive removed after the HP-UX software

activated the drive lock.

Unlock the drive using HP-UX

software.

0.1.en.04

Critical

Loop A drive link rate incorrect.
The drive in bay en is capable

of operating at the loop link rate

established by I/O module A, but is

running at a different rate.

1.

Reseat the drive to ensure that

it is properly installed.

2.

Replace the drive.

0.1.en.05

Critical

Loop B drive link rate incorrect.
The drive in bay en is capable

of operating at the loop link rate

established by I/O module B, but is

running at a different rate.

1.

Reseat the drive to ensure that

it is properly installed.

2.

Replace the drive.

Power supply error conditions

The format of a power supply error condition report is 0.2.en.ec, where:

•

0.2. identifies a power supply error.

•

en. identifies which power supply is affected

78

EMU-generated error condition reports