Requirements and overview of copy operations

• Start RAID Manager XP, and check the connection configuration as follows:

3.

Edit the configuration definition file.
Edit the configuration definition file using the TID# and LU#, which is obtained by executing the

raidscan

command as follows:

horcm0.conf

# horcmstart.sh 0

starting HORCM inst 0

HORCM inst 0 starts successfully.

# HORCMINST=0

# export HORCMINST

# HORCC_MRCF=1

# export HORCC_MRCF

# raidscan -p CL1-A -CLI

PORT# /ALPA/C TID# LU# Seq# Num LDEV# P/S Status P-Seq# P-LDEV#

CL1-A b2 2 0 0 0 60000 1 10 SMPL - - -

CL1-A b2 2 0 0 1 60000 1 10 SMPL - - -

CL1-A b2 2 0 0 2 60000 1 10 SMPL - - -

# raidscan -p CL1-B -CLI -fe

PORT# /ALPA/C TID# LU# Seq# Num LDEV# P/S Status E-Seq# E-LDEV#

CL1-B b2 2 0 0 0 60000 1 11 SMPL - 30000 12

CL1-B b2 2 0 0 1 60000 1 11 SMPL - 30000 12

CL1-B b2 2 0 0 2 60000 1 11 SMPL - 30000 12

# horcmshutdown.sh 0

inst 0:

HORCM Shutdown inst 0 !!!

HORCM_MON

#ip_address service poll(10ms) timeout(10ms)

127.0.0.1 52050 1000 3000

HORCM_CMD

#dev_name dev_name dev_name

/dev/rdsk/c1t2d3

HORCM_DEV

#dev_group dev_name port# TargetID LU# MU#

hicp hicpdev1 CL1-A 0 0 0

HORCM_INST

#dev_group ip_address service

hicp 127.0.0.1 52051